The finite element analysis ( FEA) models for 5 special-shaped ( triangular section,fan-section,Dsection,
1 /4 circular section and semicircular section) concrete-filled steel tubular stub columns with the same
perimeter of cross-section under axial compression are developed using ABAQUS software and the corresponding 6
group tests are conducted for comparison. The predicted load versus strain relationship curves and failure modes are
in good agreement with the measured results. The FEA models are then used to analyze the interaction between the
concrete and the steel tube during the whole loading process. And then,the main parameters influencing the bearing
capacity and deformation such as section shape,steel tube wall thickness,steel tube yield strength,concrete
compression strength are investigated. The results show the typical failure modes of these stub columns were the
outward bulge at about mid-height,the section shape,the steel tube wall thickness and the concrete compression
strength have obvious effects on their mechanical behavior,while the steel tube yield strength has slight effect on their
mechanical behavior.