XU Bin, QIU Junxia, GONG Zhengxuan, FENG Heng, ZENG Erxian, ZHANG Zhiwei, QIAN Hongliang, WANG Huajie. Research on the Enhancement of Compressive Performance in GRPU Non-Destructively Reinforced Single-Limb Angle Connections[J]. INDUSTRIAL CONSTRUCTION, 2026, 56(4): 300-308. doi: 10.3724/j.gyjzG24103103
Citation: XU Bin, QIU Junxia, GONG Zhengxuan, FENG Heng, ZENG Erxian, ZHANG Zhiwei, QIAN Hongliang, WANG Huajie. Research on the Enhancement of Compressive Performance in GRPU Non-Destructively Reinforced Single-Limb Angle Connections[J]. INDUSTRIAL CONSTRUCTION, 2026, 56(4): 300-308. doi: 10.3724/j.gyjzG24103103

Research on the Enhancement of Compressive Performance in GRPU Non-Destructively Reinforced Single-Limb Angle Connections

doi: 10.3724/j.gyjzG24103103
  • Received Date: 2024-10-31
    Available Online: 2026-06-06
  • Publish Date: 2026-04-20
  • With the continuous expansion of the power grid scale and the increasing demand for electricity, the load demand of transmission towers continues to rise. Studying the non-destructive reinforcement of their key components is of great theoretical significance and practical value for improving their structural function and extending their service life. Lightweight and high-strength glass-fiber reinforced polyurethane (GRPU) is used to replace steel in traditional reinforcement, and the inclined angle (single-limb angle) commonly used in transmission towers is selected as the research object. A refined finite element model of the single-limb angle before and after reinforcement was established based on the non-destructive double-sided reinforcement scheme. A compression test of the single-limb angle was designed and conducted to verify the accuracy of the finite element simulation, and the effects of the two parameters, namely reinforcement ratio and slenderness ratio. were investigated. The effects of reinforcement ratio and slenderness ratio on the failure mode and bearing capacity of reinforced single-limb angle components were analyzed, and the reinforcement mechanism of the GRPU non-destructive reinforcement scheme was revealed. The results showed that the reinforcement limited the torsional deformation of the components and improved their bending stiffness, thereby enhancing the bearing capacity of the members; with the increase of the slenderness ratio and reinforcement ratio, the reinforcement effect continued to improve. Finally, a reinforcement ratio for single-limb angles was proposed.
  • loading
  • [1]
    常政刚,庄艳秋,董伟. 输电塔带电加固技术研究与工程应用[C]// 中国机电一体化技术应用协会·第四届全国石油和化工电气设计与应用论文大赛论文集. 淄博:2020.
    [2]
    LIANG G,WANG L T,LIU Y H,et al. Mechanical behavior of steel transmission tower legs reinforced with innovative clamp under eccentric compression[J]. Engineering Structures,2022,258:1-18.
    [3]
    刘云贺,辛振科,梁刚,等. 角钢T形组合截面压弯构件受力性能试验研究[J]. 建筑结构,2022,52(24):57-63.
    [4]
    辛振科. 双角钢T形组合截面压弯构件受力性能及设计方法研究[D]. 西安:西安理工大学,2022.
    [5]
    XIN Z K,WEI H H,LIU Y H,et al. Study on mechanical properties of press-bending members based on transmission towers diagonal angle reinforcement in-situ[J]. International Journal of Steel Structures,2022,22(4):1025-1041.
    [6]
    梁刚,李桂花,耿娜娜,等. 基于新型夹具的双角钢十字组合构件偏压承载力研究[J]. 自然灾害学报,2022,31(6):113-124.
    [7]
    TEMPLE M C,SAKLA S S S,STCHYRBA D,et al. Arrangement of interconnectors for starred angle compression members[J]. Canadian Journal of Civil Engineering,1994,21(1):110348977.
    [8]
    JULIE E M,MA X,YAN Z. Experimental study on multi-panel retrofitted steel transmission towers[J]. Journal of Constructional Steel Research,2012,78:58-67.
    [9]
    JIAN X Y,LIU H Q,ZHAO Z W,et al. A study of the mechanical behavior of rectangular steel tubular column strengthened using intermittent welding angle steel[J]. Structures,2021,33:3298-3310.
    [10]
    孙启刚,吴健,刘海涛,等. 输电塔T形组合角钢加固构件承载性能试验研究[J]. 工业建筑,2018,48(12):181-186.
    [11]
    KOMATSU H,ISHII K,FUKUSHIMA A. Experimental study on buckling strength of angle steel compression members with Built-up Bracing[J]. Kou Kouzou Rombunshuu,2009,16(62):27-34.
    [12]
    WANG J T,WU X H,YANG B,et al. Retrofitted built-up steel angle members for enhancing bearing capacity of latticed towers:experiment[J]. Steel and Composite Structures,2021,41(5):681-695.
    [13]
    李艳丽,石磊,武振宇,等. 采用箱形截面加固的输电塔主杆角钢承载能力的有限元参数分析[J]. 工业建筑,2022,52(8):41-47.
    [14]
    李文斌,邱智育,马池,等. 输电线路杆塔非焊接Y字形加固技术试验研究[J]. 工业建筑,2020,50(8):120-127.
    [15]
    谢强,孙力,张勇. 500kV输电塔结构抗冰加固改造方法试验研究[J]. 中国电机工程学报,2011,31(16

    ):108-114.
    [16]
    张戬,杨正,谢强. 输电塔T形组合角钢加固方法试验研究[J]. 工业建筑,2019,49(4):37-43.
    [17]
    XIE Q,ZHANG J. Experimental study on failure modes and retrofitting method of latticed transmission tower[J]. Engineering Structures,2021,226:1-14.
    [18]
    CHEN C,TANG Y,ZHANG L,et al. Analysis of the bearing capacity of a steel structural member after reinforcement[J]. Advances in Civil Engineering,2022,2022:1-14.
    [19]
    全国钢标准化技术委员会. 金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2021

    [S]. 北京:中国标准出版社,2021.
    [20]
    全国纤维增强塑料标准化技术委员会. 纤维增强塑料性能试验方法总则:GB/T 1446—2005[S]. 北京:中国标准出版社,2005.
    [21]
    全国纤维增强塑料标准化技术委员会. 纤维增强塑料拉伸性能试验方法:GB/T 1447—2005[S]. 北京:中国标准出版社,2005.
    [22]
    国家能源局. 架空输电线路杆塔结构设计技术规定:DL/T 5154—2012[S]. 北京:中国标准出版社,2012.
    [23]
    American Society of Civil Engineers. Design of latticed steel transmission structures:A SCE 10-2015[S]. Newyork:American Society of Civil Engineers,2015.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (21) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return