Citation: | LIU Zhenlin, CHENG Yongfeng, LU Zhicheng, ZHANG Xiaojun, ZHU Zhubing, ZHANG Shujun. SHAKING TABLE TESTS OF ULTRA-HIGH-VOLTAGE TRANSFORMER MODELS WITH NONLINEAR VIBRATION ISOLATION DEVICES[J]. INDUSTRIAL CONSTRUCTION, 2021, 51(11): 19-24. doi: 10.13204/j.gyjzG21052708 |
[1] |
谢强,朱瑞元,屈文俊.汶川地震中500 kV大型变压器震害机制分析[J].电网技术,2011,35(3):221-226.
|
[2] |
孙宇晗,卢智成,刘振林,等.1 100 kV特高压套管地震模拟振动台试验[J].高电压技术,2017,43(12):4139-4144.
|
[3] |
BELLORINI S,SALVETTI M,BETTINALI F,et al.Seismic Qualification of Transformer High Voltage Bushings[J].IEEE Transactions on Power Delivery,1998,13(4):1208-1213.
|
[4] |
ANAGNOS T.Development of an Electrical Substation Equipment Performance Database for Evaluation of Equipment Fragilities[R].California:San Jose State University,1999.
|
[5] |
WHITTAKER A S,FENVES G L,GILANI A S.Earthquake Performance of Porcelain Transformer Bushings[J].Earthquake Spectra,2004,20(1):205-223.
|
[6] |
KOLIOU M,FILIATRAULT A,REINHORN A M.Seismic Response of High-Voltage Transformer-Bushing Systems Incorporating Flexural Stiffeners Ⅱ:Experimental Study[J].Earthquake Spectra,2013,29(4):1353-1367.
|
[7] |
BENDER J,FARID A.Seismic Vulnerability of Power Transformer Bushings:Complex Structural Dynamics and Seismic Amplification[J].Engineering Structures,2018,162(5):1-10.
|
[8] |
刘如山,张美晶,王翔鹰,等.基于设防烈度和震害统计的变电站震害快速评估法[J].地震工程与工程振动,2012,32(5):152-159.
|
[9] |
朱瑞民,李东亮,齐立忠,等.变电站地震灾害分析与抗震设计[J].电力建设,2013,34(4):14-18.
|
[10] |
刘彦辉,谭平,周福霖,等.大型变压器的汶川震害及其隔震技术研究[J].广州大学学报(自然科学版),2014,13(6):36-41.
|
[11] |
陈传新,刘彦辉,贺瑞,等.考虑液-固耦合的大型超高压换流变压器地震响应研究[J].地震工程学报,2017,39(3):397-403.
|
[12] |
马国梁,朱瑞元,谢强,等.变压器-套管体系基础隔震振动台试验[J].高电压技术,2017,43(4):1317-1325.
|
[13] |
宋彧.相似模型试验原理[M].北京:人民交通出版社股份有限公司,2016.
|
[14] |
卢智成,代泽兵,孟宪政,等.特高压变电设备抗震振动台试验方法研究[J].建筑结构,2013,43(增刊1):1269-1272.
|
[15] |
尤红兵,张郁山,赵凤新.电气设备振动台试验输入的合理确定[J].电网技术,2012,36(5):118-124.
|
[16] |
国家电网有限公司.特高压瓷绝缘电气设备抗震设计及减震装置安装与维护技术规程:Q/GDW 11132-2013[S].北京:中国计划出版社,2014.
|