EXPERIMENTAL RESEARCH ON ASEISMIC PERFORMANCES OF PREFABRICATED SHEAR WALL CONNECTED BY UHPC

doi: 10.13204/j.gyjzG20042601
  • Received Date: 2020-04-26
    Available Online: 2022-01-11
  • A new precast shear wall connected by ultra high performance concrete (UHPC) was introduced in the paper. 5 full-scale shear walls were designed to study the aseismic performances of the precast shear wall subjected to quasi-static cyclic loads. The experiment results showed that the prefabricated shear wall with horizontal joints and the cast-in-place wall failed in the same compression-bending mode, the concrete at the bottom of the prefabricated shear wall crushed badly. The shear wall with vertical joints failed in bending-shear mode while a subtle sidesway was observed and the vertical rebars ruptured. For the prefabricated shear wall in the axial compression ratio of 0.35, the thickness of the protective layer of UHPC was small because of the poor quality of the casting, resulting in insufficient anchoring of the rebars in the post-casting area. The new connection form could transfer the stress of rebars effectively, the shear wall with horizontal joints or vertical joints showed slightly higher bearing capacity than the cast-in-place in same axial compression ratio, and the displacement ductility and energy-dissipation capacity were extremely closed. The ultimate shift angles of the 5 shear walls were larger than 1/100, meeting the requirements of GB 50011-2010 Code for Seismic Design of Building.
  • loading
  • [1]
    钱稼茹, 杨新科, 秦珩, 等. 竖向钢筋采用不同连接方法的预制钢筋混凝土剪力墙抗震性能试验[J]. 建筑结构学报, 2011,32(6):51-59.
    [2]
    钱稼茹, 彭媛媛, 张景明, 等. 竖向钢筋套筒浆锚连接的预制剪力墙抗震性能试验[J]. 建筑结构,2011,41(2):1-6.
    [3]
    李刚, 黄小坤, 刘瑄, 等. 底部预留后浇区钢筋搭接的装配整体式剪力墙抗震性能试验研究[J]. 建筑结构学报, 2016, 37(5):193-200.
    [4]
    陈建伟, 苏幼坡. 预制装配式剪力墙结构及其连接技术[J]. 世界地震工程, 2013(1):40-50.
    [5]
    薛伟辰, 胡翔. 预制混凝土建筑结构体系研究进展概述[J]. 施工技术, 2018, 47(12):6-10

    ,48.
    [6]
    GU Q, DONG G, WANG X, et al. Research on Pseudo-Static Cyclic Tests of Precast Concrete Shear Walls with Vertical Rebar Lapping in Grout-Filled Constrained Hole[J]. Engineering Structures, 2019, 189(3):396-410.
    [7]
    杨勇. 带竖向结合面预制混凝土剪力墙抗震性能试验研究[D]. 哈尔滨:哈尔滨工业大学, 2011.
    [8]
    王瑞龙, 马骉. 钢筋与超高性能混凝土黏结锚固试验研究[J]. 城市道桥与防洪, 2018(9):204-207,22

    -23.
    [9]
    SHAFIEIFAR M, FARZAD M, AZIZINAMINI A. Experimental and Numerical Study on Mechanical Properties of Ultra High Performance Concrete (UHPC)[J]. Construction and Building Materials, 2017,156:402-411.