Zhu Zhijun Zhang Qing Tan Yongqiang Zhou Xiangjiang, . RESEARCH ON EQUIVALENT ANALYSIS OF TRUSS BEAMS OF PREFABRICATED STEEL FRAME STRUCTURE WITH DIAGONAL BRACING JOINTS[J]. INDUSTRIAL CONSTRUCTION, 2015, 45(10): 24-30. doi: 10.13204/j.gyjz201510005
Citation:
Zhu Zhijun Zhang Qing Tan Yongqiang Zhou Xiangjiang, . RESEARCH ON EQUIVALENT ANALYSIS OF TRUSS BEAMS OF PREFABRICATED STEEL FRAME STRUCTURE WITH DIAGONAL BRACING JOINTS[J]. INDUSTRIAL CONSTRUCTION , 2015, 45(10): 24-30. doi: 10.13204/j.gyjz201510005
Zhu Zhijun Zhang Qing Tan Yongqiang Zhou Xiangjiang, . RESEARCH ON EQUIVALENT ANALYSIS OF TRUSS BEAMS OF PREFABRICATED STEEL FRAME STRUCTURE WITH DIAGONAL BRACING JOINTS[J]. INDUSTRIAL CONSTRUCTION, 2015, 45(10): 24-30. doi: 10.13204/j.gyjz201510005
Citation:
Zhu Zhijun Zhang Qing Tan Yongqiang Zhou Xiangjiang, . RESEARCH ON EQUIVALENT ANALYSIS OF TRUSS BEAMS OF PREFABRICATED STEEL FRAME STRUCTURE WITH DIAGONAL BRACING JOINTS[J]. INDUSTRIAL CONSTRUCTION , 2015, 45(10): 24-30. doi: 10.13204/j.gyjz201510005
RESEARCH ON EQUIVALENT ANALYSIS OF TRUSS BEAMS OF PREFABRICATED STEEL FRAME STRUCTURE WITH DIAGONAL BRACING JOINTS
Abstract
Due to the difficulty to do structural calculation and the big quantity of truss beam members in the prefabricated steel frame structure with diagonal bracing,this paper proposed a simplified calculation method by equating steel truss beams with solid I-steel beams according to the principle of equal stiffness,equal height and equal flanges. 5 equivalent beam sections figures were obtained by considering the 4 boundary conditions: simply supported beam subject to uniform loads,simply supported beam subject to point loads at mid-span,cantilever beam subject to uniform loads and cantilever beam subject to point loads at free end. SAP 2000 was applied to build an actual structural calculation model and equivalent ones of a 20-storey prefabricated steel frame structure with diagonal bracing joints. The structural calculation was performed to give a comparison of the key indexes such as mode periods,drift,inter-story drift angle,shear-weight ratio,rigidity-to-gravity ratio and so on. The best match happened between the results achieved in the boundary condition of simply supported beam subject to uniform loads and the actual model. It was proved that this method could be used in integral structure analysis and design for the prefabricated steel frame structure with diagonal bracing and other similar structures.
References
Relative Articles
[1] LIU Chengqing, XU Dibing, ZHANG Huaxin. Seismic Strengthening Design and Analysis of a Boiler Steel Frame [J]. INDUSTRIAL CONSTRUCTION, 2024, 54(3): 237-245. doi: 10.13204/j.gyjzG22050603
[2] JIN Chenhua, WU Chang, PAN Zuanfeng, MENG Shaoping. Calculation of Shear Capacity of Shear Walls with Small Shear-Span Ratio Based on Equivalent Diagonal Web Truss-Arch Model [J]. INDUSTRIAL CONSTRUCTION, 2023, 53(9): 111-118. doi: 10.13204/j.gyjzG22091505
[5] Shu Xingping Zhao Kai Yuan Zhishen Lu Beirong, . RESEARCH ON THE INFLUENCE OF VERTICAL DEFORMATIONS IN CONSTRUCTION SIMULATION OF PREFABRICATED STEEL FRAME STRUCTURE WITH INCLINED SUPPORT JOINTS [J]. INDUSTRIAL CONSTRUCTION, 2015, 45(10): 42-47. doi: 10.13204/j.gyjz201510008
[6] Zhang Ailin, Hui Yi, Liu Xuechun. SEISMIC PERFORMANCE RESEARCH ON BEAM-COLUMN SPLICE JOINTS OF PREFABRICATED STEEL FRAMED STRUCTURES WITH BRACES [J]. INDUSTRIAL CONSTRUCTION, 2014, 44(08): 35-38.
[7] Zhang Ailin, Tian Chen, Liu Xuechun. EFFECTIVE LENGTH ANALYSIS OF TRUSS BEAM WEB MEMBER OF INDUSTRIAL PREFABRICATED HIGH-RISE STEEL STRUCTURE [J]. INDUSTRIAL CONSTRUCTION, 2014, 44(12): 128-131. doi: 10.13204/j.gyjz2001412021
[8] Li Yongjing, Zhang Jing, Zhang Xu. THE VIBRATION CONTROL EFFECT ANALYSIS OF TORSION COUPLING RESPONSE OF ECCENTRIC STRUCTURES WITH THE VISCOUS DAMPERS [J]. INDUSTRIAL CONSTRUCTION, 2013, 43(5): 68-72. doi: 10.13204/j.gyjz201305015
[9] Hu Kongpeng, Chen Daozheng. EFFECTS OF LAYERS AND FLOOR HEIGHT ON QUANTITY OF SHEAR WALLS IN TALL BUILDINGS [J]. INDUSTRIAL CONSTRUCTION, 2013, 43(3): 67-70. doi: 10.13204/j.gyjz201303014
[10] Guo Zhen, Yuan Yingshu. SHEAR STRENGTH OF NOVEL STEEL PLATE COMPOSITE SHEAR WALL [J]. INDUSTRIAL CONSTRUCTION, 2012, 42(1): 154-159,88. doi: 10.13204/j.gyjz201201030
[11] Wang Zhijun, Zhu Lanying, Yu Binning, Luo Lai’an. EXPERIMENTAL INVESTIGATION AND FINITE ELEMENT ANALYSIS OF TRUSS BEAM OF NEST LIGHT-GAUGE STEEL SYSTEM [J]. INDUSTRIAL CONSTRUCTION, 2011, 41(12): 111-115. doi: 10.13204/j.gyjz201112025
[12] Zhang Xuewei, Liu Weidong, Zhang Li, Zhao Yan, Yan Yinkun. RENOVATION AND REINFORCEMENT DESIGN OF A FRAMED OFFICE BUILDING [J]. INDUSTRIAL CONSTRUCTION, 2011, 41(2): 123-126,122. doi: 10.13204/j.gyjz201102028
[13] Liu Lin, Bai Guoliang, Li Xiaowen, Li Hongxing, Zhao Chunlian. DISPLACEMENT-BASED SEISMIC DESIGN METHOD OF RC FRAMES [J]. INDUSTRIAL CONSTRUCTION, 2009, 39(5): 1-5. doi: 10.13204/j.gyjz200905001
[14] Li Haifang, Gong Xiaonan, Wen Xiaogui. ANALYSIS OF DISPLACEMENT IN DIFFERENT DEPTH OF LOW-STRENGTH PILE COMPOSITE FOUNDATION [J]. INDUSTRIAL CONSTRUCTION, 2005, 35(1): 47-49. doi: 10.13204/j.gyjz200501014
[15] Wu Qiang, Cheng Wenrang. STUDY OF CALCULATING WIDTH OF EQUIVALENT BEAM FOR SLAB-COLUMN STRUCTURE SUBJECTED TO HORIZONTAL FORCES [J]. INDUSTRIAL CONSTRUCTION, 2004, 34(3): 77-79. doi: 10.13204/j.gyjz200403024
Cited by Periodical cited type(1) 1. 郝际平,薛强,郭亮,孙晓岭. 装配式多、高层钢结构住宅建筑体系研究与进展. 中国建筑金属结构. 2020(03): 27-34 .
Other cited types(3)
Proportional views