Huang Guo-hong, Chen Fu-lin, Xie Shu-ilan, Du Yan-fei, Tang Wei. WATERPROOF MEASURES OF PRECAST WALL PANEL SYSTEM OF SINGAPORE UNIVERSAL STUDIO PROJECT[J]. INDUSTRIAL CONSTRUCTION, 2012, 42(9): 6-10. doi: 10.13204/j.gyjz201209002
Citation:
Huang Guo-hong, Chen Fu-lin, Xie Shu-ilan, Du Yan-fei, Tang Wei. WATERPROOF MEASURES OF PRECAST WALL PANEL SYSTEM OF SINGAPORE UNIVERSAL STUDIO PROJECT[J]. INDUSTRIAL CONSTRUCTION , 2012, 42(9): 6-10. doi: 10.13204/j.gyjz201209002
Huang Guo-hong, Chen Fu-lin, Xie Shu-ilan, Du Yan-fei, Tang Wei. WATERPROOF MEASURES OF PRECAST WALL PANEL SYSTEM OF SINGAPORE UNIVERSAL STUDIO PROJECT[J]. INDUSTRIAL CONSTRUCTION, 2012, 42(9): 6-10. doi: 10.13204/j.gyjz201209002
Citation:
Huang Guo-hong, Chen Fu-lin, Xie Shu-ilan, Du Yan-fei, Tang Wei. WATERPROOF MEASURES OF PRECAST WALL PANEL SYSTEM OF SINGAPORE UNIVERSAL STUDIO PROJECT[J]. INDUSTRIAL CONSTRUCTION , 2012, 42(9): 6-10. doi: 10.13204/j.gyjz201209002
WATERPROOF MEASURES OF PRECAST WALL PANEL SYSTEM OF SINGAPORE UNIVERSAL STUDIO PROJECT
Received Date: 2012-04-28
Publish Date:
2012-09-20
Abstract
Combined with the outer wall system, which was used for the first time in Singapore Universal Studio Project, it is deeply studied the waterproof of buildings'outer wall in high-temperature and rainy areas, and carried out optimal design of waterproof starting from the materials and structure.This study provides many useful waterproof joint designs of precast concrete panel and autoclaved light-weight concrete (ALC) wall panel.
References
顾自翀,朱斌,陈浙军.住宅楼预制复合保温外墙板防水技术[J].中国建筑防水,2010(16): 20-23.
[3] 冯诗斌.建筑外墙板缝构造防水施工的方法探讨[J].科技传播,2011(2): 50-51.
[4] 牛培栋,丁亮,谭斌,等.ALC 墙板的施工技术研究[J].青岛理工大学学报,2011(6): 129-132.
[5] 张浩.苏州博物馆新馆防水设计[J].中国建筑防水,2006(4): 26-29.