Source Journal for Chinese Scientific and Technical Papers
Core Journal of RCCSE
Included in JST China
Included in the Hierarchical Directory of High-quality Technical Journals in Architecture Science Field
Volume 42 Issue 7
Dec.  2014
Turn off MathJax
Article Contents
Tang Hongyuan, Wang Zeyun, Jia Yigang. ASSESSMENT AND STRENGTHEN FOR A CHEMICAL FIBRE FACTORY BUILDING SUBJECTED TO FIRE DISASTER[J]. INDUSTRIAL CONSTRUCTION, 2012, 42(7): 152-155,170. doi: 10.13204/j.gyjz201207026
Citation: Tang Hongyuan, Wang Zeyun, Jia Yigang. ASSESSMENT AND STRENGTHEN FOR A CHEMICAL FIBRE FACTORY BUILDING SUBJECTED TO FIRE DISASTER[J]. INDUSTRIAL CONSTRUCTION, 2012, 42(7): 152-155,170. doi: 10.13204/j.gyjz201207026

ASSESSMENT AND STRENGTHEN FOR A CHEMICAL FIBRE FACTORY BUILDING SUBJECTED TO FIRE DISASTER

doi: 10.13204/j.gyjz201207026
  • Received Date: 2011-11-15
  • Publish Date: 2012-07-20
  • The test methods and contents for a factory building subjected to fire disaster were introduced, includingsection geometry size, concrete strength, steel strength, and carbonation depth in concrete and so on. The firedamaged structure was appraised according to the test results and calculation. The adapted strengthening methodswere put forward through the specific appraisal results. The damaged columns were respectively strengthened withreinforced concrete, externally bonded steel frame and carbon fiber reinforced polymer. For the damaged beams, demolition replacement, strengthened with externally bonded steel frame and carbon fiber reinforced polymer wereused respectively; for the damaged slabs, the demolition replacement, bottom bonded rebar with shotcrete andexternally bonded carbon fiber reinforced polymer were used. The structure completely resumed its bearing capacityafter strengthening.
  • loading
  • CECS 252:2009火灾后建筑结构鉴定标准[S].
    [2] 陆洲导,朱伯龙.混凝土结构火灾后的加固修复[J].工业建筑,1997,27(1):6-10.
    [3] 范进,吕志涛.高温(火灾)下预应力钢丝性能的试验研究[J].建筑技术,2001(12):833-834.
    [4] GB501442008工业建筑可靠性鉴定标准[S].
    [5] GB503672006混凝土结构加固设计规范[S].
    [6] CECS146:2003碳纤维片材加固混凝土结构技术规程[S].
    [7] 唐叶清,万墨林.建筑物改造与病害处理[M].北京:中国建筑工业出版社,2000.
    [8] 唐红元,贾益纲.一种RC梁加固后的短期刚度计算方法[J].南昌大学学报:工科版,2003,25(1):48-50.
    [9] 范进,吕志涛.火灾后预应力混凝土结构的评估与处理[J].建筑技术,2003,34(6):423-425.
    [10] 卜良桃,陈军,黎红兵.火灾后混凝土结构检测和加固技术研究[J].工业建筑,2009,39(6):117-119.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (101) PDF downloads(76) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return