Li Yan, Hao Jiping, Zhou Qi, Xie Qi, Guo Hongchao. EXPERIMENTAL STUDY AND FINITE ELEMENT ANALYSIS OF STEEL PLATE SHEAR WALL WITH UNSTIFFENED WELDED-BOLTED CONNECTIONS[J]. INDUSTRIAL CONSTRUCTION, 2011, 41(7): 101-106,100. doi: 10.13204/j.gyjz201107023
Citation: Li Yan, Hao Jiping, Zhou Qi, Xie Qi, Guo Hongchao. EXPERIMENTAL STUDY AND FINITE ELEMENT ANALYSIS OF STEEL PLATE SHEAR WALL WITH UNSTIFFENED WELDED-BOLTED CONNECTIONS[J]. INDUSTRIAL CONSTRUCTION, 2011, 41(7): 101-106,100. doi: 10.13204/j.gyjz201107023

EXPERIMENTAL STUDY AND FINITE ELEMENT ANALYSIS OF STEEL PLATE SHEAR WALL WITH UNSTIFFENED WELDED-BOLTED CONNECTIONS

doi: 10.13204/j.gyjz201107023
  • Received Date: 2010-12-10
  • Publish Date: 2011-07-20
  • In the steel plate shear wall,pulling force of the steel plate can change the force transmission path in the frame.The horizontal component of forces in the upper and lower plates act on the beam,thus bending moment of the beam is reduced.The stiffness requirements of connections can also be reduced.This makes semi-rigid connections possible.Up to this point,the concept of a new type structure named semi-rigid steel frame-steel plate shear wall is presented.In this paper,a single-span and two-story steel plate shear wall with unstiffened welded-bolted connections is designed and low-cycle reverse loading tests and finite element analysis are carried out.There are four conclusions can be drawn: Firstly,the new structure has high ultimate strength and good energy dissipation.Secondly,pulling strips of the first story are more obvious than those of the second story.Thirdly,the steel plate can bear 65.28%~73.87% of lateral load,and 21.98%~33.35% of overturning moment;Fourthly,the connection is not the weak location of the new structure,and semi-rigid connection is reasonable.
  • loading
  • [2] Darren Vian, Michel Bruneau, Ronny Purba. Special Perforated Steel Plate Shear Walls with Reduced Beam Section Anchor Beams. II; Analysis and Design Recommendations[J]. Journal of Structural Engineering,2009,135(3);221-228.
    Darren Vian, Michel Bruneau, Tsai K C, et al. Special Perforated Steel Plate Shear Walls with Reduced Beam Section Anchor Beams. I; Experimental Investigation[J]. Journal of Structural Engineering,2009,135(3);211-220.
    [3] 蔡克铨,林盈成,林志翰.钢板剪力墙抗震行为与设计[J].建筑钢结构进展,2007,9(5);19-25.
    [4] 陆烨,李国强,孙飞飞.大高宽比屈曲约束组合钢板剪力墙的试验研究[J].建筑钢结构进展,2009,11(2);18-27.
    [5] 孙飞飞,戴成华,李国强.大宽厚比开缝组合钢板墙低周反复荷载试验研究[J].建筑结构学报,2009,30(5);72-81.
    [6] 郭彦林,董全利,周明.防屈曲钢板剪力墙滞回性能理论与试验研究[J].工程力学,2009,30(1);108-114.
    [7] 郝际平,曹春华,王迎春,等.开洞薄钢板剪力墙低周反复荷载试验研究[J].地震工程与工程振动,2009,29(2);79-85.
    [8] 李峰,李慧,李振敏,等.交叉加劲肋钢板剪力墙低周反复荷载试验研究[J].西安建筑科技大学学报;自然科学版,2009,41(1);57-62.
    [9] JGJ 10196建筑抗震试验方法规程[S].
    [10] 姚谦峰,陈平.土木工程结构试验[M].北京;中国建筑工业出版社,2001.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (68) PDF downloads(88) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return