Liu Jinwei, Xiong Guangjing. DETECTION AND ANALYSIS OF CRACKED CONCRETE COLUMN FOR A DWELLING BUILDING IN SHANTOU[J]. INDUSTRIAL CONSTRUCTION, 2007, 37(1): 110-112. doi: 10.13204/j.gyjz200701028
Citation: Liu Jinwei, Xiong Guangjing. DETECTION AND ANALYSIS OF CRACKED CONCRETE COLUMN FOR A DWELLING BUILDING IN SHANTOU[J]. INDUSTRIAL CONSTRUCTION, 2007, 37(1): 110-112. doi: 10.13204/j.gyjz200701028

DETECTION AND ANALYSIS OF CRACKED CONCRETE COLUMN FOR A DWELLING BUILDING IN SHANTOU

doi: 10.13204/j.gyjz200701028
  • Received Date: 2006-04-20
  • Publish Date: 2007-01-20
  • The detection for concrete column cracking of a dwelling building by detecting chlorine ion in the concrete,concrete cover thickness and degree of steel-bar corrosion was completed.The result of detection and analysis indicated that the main reason of column cracking was that the content of chlorine ion in concrete was higher.The distributive rules of chlorine ion in concrete column were also discussed.