Wang Rui, Guo Zhaosheng, Cui Juanling. THE SPOT TESTING AND FEA OF THE VIBRATION BEHAVIOR OF BEAM-PLATES SYSTEM CAUSED BY THE VIBRATION OF FLUIDIZED BED DRYER[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(09): 62-67.
Citation:
Wang Rui, Guo Zhaosheng, Cui Juanling. THE SPOT TESTING AND FEA OF THE VIBRATION BEHAVIOR OF BEAM-PLATES SYSTEM CAUSED BY THE VIBRATION OF FLUIDIZED BED DRYER[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(09): 62-67.
Wang Rui, Guo Zhaosheng, Cui Juanling. THE SPOT TESTING AND FEA OF THE VIBRATION BEHAVIOR OF BEAM-PLATES SYSTEM CAUSED BY THE VIBRATION OF FLUIDIZED BED DRYER[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(09): 62-67.
Citation:
Wang Rui, Guo Zhaosheng, Cui Juanling. THE SPOT TESTING AND FEA OF THE VIBRATION BEHAVIOR OF BEAM-PLATES SYSTEM CAUSED BY THE VIBRATION OF FLUIDIZED BED DRYER[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(09): 62-67.
The vibration behavior of beam-plates system caused by the vibration of fluidized bed dryer was tested. The
disturbing force and frequency of vibrating equipment,working performance of the existing isolation bearing and
response of floor vibration was obtained. According to the spot test results, finite element analysis of simple harmonic
vibration was carried out by ANSYS software. The test results show that floor vibration response is larger in frame
regions having vibration equipment; vibration response of monitoring points on frame beam is much less than that of
monitoring points on secondary beam,vibration response of measuring points decay soon along the floor longitudinal
points. The linear superposition comprehensive vibration effect of multiple vibration equipment can be regarded as a
single vibration equipment vibration effect,the main cause of factory floor of big vibration is forced resonance. Based
on a simply continuous orthotropic plate model and the eigenfrequency sensitivity analysis technique,the optimal
modifying position and revisions of the structural stiffness were acquired. Lastly,the vibration reduction treatment
scheme was proposed.