Liu Xuechun, Xu Axin, Ni Zhen, Zhang Ailin. ANALYSIS OF THE LIMIT BEARING CAPACITY AND SEISMIC PERFORMANCE OF TYPICAL JOINT OF TRUSS-BEAM AND COLUMN IN FABRICATED HIGH-RISE STEEL STRUCTURE[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(08): 23-26.
Citation:
Liu Xuechun, Xu Axin, Ni Zhen, Zhang Ailin. ANALYSIS OF THE LIMIT BEARING CAPACITY AND SEISMIC PERFORMANCE OF TYPICAL JOINT OF TRUSS-BEAM AND COLUMN IN FABRICATED HIGH-RISE STEEL STRUCTURE[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(08): 23-26.
Liu Xuechun, Xu Axin, Ni Zhen, Zhang Ailin. ANALYSIS OF THE LIMIT BEARING CAPACITY AND SEISMIC PERFORMANCE OF TYPICAL JOINT OF TRUSS-BEAM AND COLUMN IN FABRICATED HIGH-RISE STEEL STRUCTURE[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(08): 23-26.
Citation:
Liu Xuechun, Xu Axin, Ni Zhen, Zhang Ailin. ANALYSIS OF THE LIMIT BEARING CAPACITY AND SEISMIC PERFORMANCE OF TYPICAL JOINT OF TRUSS-BEAM AND COLUMN IN FABRICATED HIGH-RISE STEEL STRUCTURE[J]. INDUSTRIAL CONSTRUCTION, 2014, 44(08): 23-26.
Welded joints,bolted joints,bolted and welded joints are the typical joints in fabricated high-rise steel
structure. The paper established three models of the joints of truss-beam and column for nonlinear analysis using the
finite element software ABAQUS,it was got that the failure mechanism, the limit bearing capacity and the energy
dissipation capacity that was the one in the function of monotonic cyclic load. The results show that the limit bearing
capacity of the welded joint is the highest,but the plastic deformation mainly appears in joint region, so it dissatisfies
the seismic request. The slip occurs easily in frictional regions for the bolted joint in the function of monotonic cyclic
load. The out-of-plane buckling of the overall truss-beam in bolted and welded joint occurs due to the different
stiffness of the two sections of the single beam-truss. So the limit bearing capacity of this joint is the lowest. It was
proposed that some suggestions on the design of three typical joints of truss-beam and column in fabricated high-rise
steel structure.