Source Journal for Chinese Scientific and Technical Papers
Core Journal of RCCSE
Included in JST China
Included in the Hierarchical Directory of High-quality Technical Journals in Architecture Science Field
Volume 54 Issue 8
Aug.  2024
Turn off MathJax
Article Contents
ZHANG Zeyu, ZENG Lijing, WANG Yuedong, HOU Zhaoxin, LIU Xuechun, ZHANG Ailin, LI Weinan. Research on Mechanical Properties of Prefabricated Z-Shaped Steel Beam-to-Column Connections[J]. INDUSTRIAL CONSTRUCTION, 2024, 54(8): 62-69. doi: 10.3724/j.gyjzG24022007
Citation: ZHANG Zeyu, ZENG Lijing, WANG Yuedong, HOU Zhaoxin, LIU Xuechun, ZHANG Ailin, LI Weinan. Research on Mechanical Properties of Prefabricated Z-Shaped Steel Beam-to-Column Connections[J]. INDUSTRIAL CONSTRUCTION, 2024, 54(8): 62-69. doi: 10.3724/j.gyjzG24022007

Research on Mechanical Properties of Prefabricated Z-Shaped Steel Beam-to-Column Connections

doi: 10.3724/j.gyjzG24022007
  • Received Date: 2024-02-20
    Available Online: 2024-09-19
  • The experiments under monotonic and cyclic loading conditions and simulation were conducted to investigate the mechanical properties of prefabricated Z-shaped steel beam-to-column connections. The rotational stiffness, failure mode, bearing capacity, hysteretic performance, energy dissipation, and stiffness degradation of Z-shaped connections with different designed strengths were studied respectively. The results showed that the prefabricated Z-shaped steel beam-to-column connections showed good ductility and could achieve plastic hinge movement outside the panel zone. The designed strength showed a significant effect on the hysteretic performance and plastic bending resistance of Z-shaped connections. The small value of designed strength parameter (0.2-0.9) made that the failure mode of Z-shaped connections was premature damage of bolts. The anti-slip and ultimate bearing capacity of Z-shaped connections increased linearly with the increase of designed strength, and the rotational performance of Z-shaped connections was semi-rigid. In case of the large value of designed strength parameter (0.9-1.3), anti-slip and ultimate bearing capacity of Z-shaped connections were almost unchanged. The failure mode was changed to premature damage of connected members, and the rotational performance of Z-shaped connections was rigid. In addition, the number of bolts required by the proposed Z-shaped connections was relatively small, and the installation was efficient and economical, which could contribute to engineering application.
  • loading
  • [1]
    MAHIN S A, MALLEY J O, HAMBURGER R O, et al. Overview of the US program for reduction of earthquake hazards in steel moment-frame structures [J]. Earthquake Spectra, 2003, 19(2): 237-254.
    [2]
    ZENG L J, ZHANG W Y, LI H W. Low-cycle fatigue life prediction of I-shaped steel brace components and braced frames[J]. Thin-Walled Structures, 2021, 163, 107711.
    [3]
    CALLISTER J T, PEKELNICKY R G. Seismic evaluation of an existing low ductility braced frame building in California [C]//Structures Congress, 2011. 2011: 2756-2767.
    [4]
    CLIFTON C, BRUNEAU M, MACRAE G, et al. Steel structures damage from the Christchurch earthquake series of 2010 and 2011[J]. Bulletin of the New Zealand Society for Earthquake Engineering, 2011, 44(4): 297-318.
    [5]
    张爱林.工业化装配式高层钢结构体系创新、标准规范编制及产业化关键问题[J].工业建筑,2014,44(8):1-6

    ,38.
    [6]
    李启才,苏明周,顾强,等.带悬臂梁段拼接的梁柱连接循环荷载试验研究[J].建筑结构学报,2003(4):54-59.
    [7]
    MONTUORI R, NASTRI E, PILUSO V. Theory of plastic mechanism control: A new approach for the optimization of seismic resistant steel frames[J]. Earthquake Engineering & Structural Dynamics, 2022, 51(15): 3598-3619.
    [8]
    叶继红,许玲玲.基于MDEM的非线性半刚性空间钢框架的弹塑性动力分析[J/OL].工程力学,1-13 [2023-09-15

    ].https://kns.cnki.net/kcms/detail/11.2595.o3.20230410.1011.006.html.
    [9]
    NGUYEN P C, KIM S E. An advanced analysis method for three-dimensional steel frames with semi-rigid connections[J]. Finite Elements in Analysis and Design, 2014, 80: 23-32.
    [10]
    夏军武,徐博,张海威,等.带填充墙的悬臂梁拼接钢框架抗震性能研究[J].建筑结构学报, 2016, 37(11):113-120.
    [11]
    ZHANG A L, LI R, JIANG Z Q, et al. Experimental study of earthquake-resilient PBCSC with double flange cover plates[J]. Journal of Constructional Steel Research, 2018, 143: 343-356.
    [12]
    ZHANG A L, ZHANG H, JIANG Z Q, et al. Low cycle reciprocating tests of earthquake-resilient prefabricated column-flange beam-column joints with different connection forms[J]. Journal of Constructional Steel Research, 2020, 164, 105771.
    [13]
    LIN X C, CHEN Y, YAN J B, et al. Seismic behavior of welded beam-to-column joints of high-strength steel-moment frame with replaceable damage-control fuses[J]. Journal of Structural Engineering, 2020, 146(8), 04020143.
    [14]
    中国钢结构协会.多高层建筑全螺栓连接装配式钢结构技术标准:T/CSCS 012—2021[S]. 北京:中国建筑工业出版社, 2021.
    [15]
    ZHANG A L, GUO Z P, LIU X C. Seismic performance of Z-type cantilever beam splices of column-tree connection[J]. Journal of Constructional Steel Research, 2017, 133: 97-111.
    [16]
    王燕, 李华军, 厉见芬. 半刚性梁柱节点连接的初始刚度和结构内力分析[J]. 工程力学, 2003, 20(6):65-69.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (70) PDF downloads(3) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return