CHEN Shuhui, XIA Zhanghua, WU Zelin, XU Yousheng, HU Mingliang, ZHU Sanfan. The Shear Bearing Capacity of Prefabricated UHPC Utility Tunnels[J]. INDUSTRIAL CONSTRUCTION, 2023, 53(5): 158-164. doi: 10.13204/j.gyjzG22010413
Citation: CHEN Shuhui, XIA Zhanghua, WU Zelin, XU Yousheng, HU Mingliang, ZHU Sanfan. The Shear Bearing Capacity of Prefabricated UHPC Utility Tunnels[J]. INDUSTRIAL CONSTRUCTION, 2023, 53(5): 158-164. doi: 10.13204/j.gyjzG22010413

The Shear Bearing Capacity of Prefabricated UHPC Utility Tunnels

doi: 10.13204/j.gyjzG22010413
  • Received Date: 2022-01-04
  • In order to study the shear bearing capacity of prefabricated UHPC utility tunnels under static loads, the shear resistance calculation method of existing box-shape concrete structures was analyzed, and the tensile effect of steel fibers on the structure was considered, and a shear bearing capacity calculation method of prefabricated UHPC utility tunnels was proposed. Combining with the static tests under bidirectional loads on prefabricated UHPC utility tunnels, the proposed calculation formula for the shear bearing capacity was analyzed, compared and verified. The results indicated that the theoretically calculated values of the shear bearing capacity of top plates and side walls for the utility tunnel structure in destruction under confining pressure, which was considered the contribution of steel fibers in UHPC to shear resistance of structures and was referred to the "internal force arch" calculation model of box-shaped structurs, were closer to the measured values in tests. The calculated results were more accurate, and the calculation errors were within 7%. Compared with the existing calculation methods, the proposed method was more accurate.
  • loading
  • [1]
    曹生龙. 预制混凝土箱涵在地下综合管廊中应用的一些技术问题探讨 [J]. 混凝土与水泥制品, 2017(7): 30-37.
    [2]
    DUGAT J, ROUX N, BERNIER G. Mechanical properties of reactive powder concretes[J]. Materials & Structures, 1996, 29(4): 233-240.
    [3]
    WU X, HAN S M. First diagonal cracking and ultimate shear of I-shaped reinforced girders of ultra-high performance fiber reinforced concrete without stirrup [J]. International Journal of Concrete Structures & Materials, 2009, 3(1): 47-56.
    [4]
    BABY F, MARCHAND P, TOUTLEMONDE F. Shear behavior of ultrahigh performance fiber-reinforced concrete beams (II): analysis and design provisions [J/OL]. Journal of Structural Engineering, 2013, 140[2022-01-04].http://10.1061/(ASCE)ST.1943-541X.0000908.
    [5]
    VOO Y L, POON W K, FOSTER S J. Shear strength of steel fiber-reinforced ultrahigh-performance concrete beams without stirrups [J/OL]. Journal of Structural Engineering, 2010, 136(11) [2022-01-04].https://doi.org/10.1061/(ASCE)ST.1943-541X.0000234.
    [6]
    刘超, 吉赫. 超高性能混凝土-混凝土组合梁抗剪承载力计算方法 [J]. 同济大学学报(自然科学版), 2019, 47(8): 1123-1130.
    [7]
    陈红波. 配筋超高性能混凝土短梁受剪性能研究 [D]. 长沙:湖南大学, 2014.
    [8]
    马熙伦, 陈宝春, 杨艳, 等. R-UHPC梁的抗剪承载力计算方法 [J]. 交通运输工程学报, 2017, 17(5): 16-26.
    [9]
    刘亮. 超高性能混凝土梁抗剪性能研究 [D]. 西安:长安大学, 2018.
    [10]
    戚家南, 王景全, 周凯, 等. UHPC梁受剪性能试验与抗剪承载力计算方法 [J]. 中国公路学报, 2020, 33(7): 95-103.
    [11]
    DINH H H, PARRA-MONTESINOS G J, WIGHT J K. Shear behavior of steel fiber-reinforced concrete beams without stirrup reinforcement [J]. Structural Journal, 2010, 107(5): 597-606.
    [12]
    DINH H H, PARRA-MONTESINOS G J, ASCE M, et al. Shear strength model for steel fiber reinforced concrete beams without stirrup reinforcement [J]. Journal of Structural Engineering, 2011, 137(10): 1039-1051.
    [13]
    徐海宾. HRB500钢筋预应力超高性能混凝土梁受力性能研究 [D]. 北京:北京工业大学, 2015.
    [14]
    XIA J, MACKIE K R, SALEEM M A, et al. Shear failure analysis on ultra-high performance concrete beams reinforced with high strength steel [J]. Engineering Structures, 2011, 33(12): 3597-609.
    [15]
    邵旭东, 杨志杰, 邹同琛, 等. 密集横隔板UHPC箱梁桥面板双向受力性能试验 [J]. 中国公路学报, 2016, 29(8): 43-49

    ,66.
    [16]
    陈艳平, 王华. 利用UHPC建设地下综合管廊的初步探讨 [J]. 市政技术, 2018, 36(6): 144-146

    ,76.
    [17]
    中华人民共和国住房和城乡建设部.混凝土结构设计规范:GB 50010—2010 [S].北京:中国建筑工业出版社,2010.
    [18]
    中华人民共和国交通运输部.公路钢筋混凝土及预应力混凝土桥涵设计规范:JTG 3362—2018 [S].北京:人民交通出版社,2018.
    [19]
    中国工程建设标准化协. 纤维混凝土结构技术规程:CECS 38∶2004 [S].北京:中国计划出版社,2004.
    [20]
    中华人民共和国建设部.普通混凝土力学性能试验方法标准:GB/T 50081—2002 [S].北京:中国建筑工业出版社,2003.
    [21]
    中华人民共和国国家质量监督检验检疫总局.活性粉末混凝土:GB/T 31387—2015 [S].北京:中国标准出版社,2015.
    [22]
    中华人民共和国国家质量监督检验检疫总局.金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2010 [S]. 北京:中国标准出版社,2011.
    [23]
    田子玄. 装配叠合式混凝土地下综合管廊受力性能试验研究 [D]. 哈尔滨:哈尔滨工业大学, 2016.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (84) PDF downloads(6) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return