WANG Zhiyuan, HU Zujun, LI Sheng, LI Suchao, LIU Zhenliang. SHAKING TABLE TESTS OF VERTICAL ISOLATION FOR TRANSFORMER MODELS BASED ON METALLIC RUBBER CUSHION AND SPRINGS[J]. INDUSTRIAL CONSTRUCTION, 2021, 51(11): 7-12. doi: 10.13204/j.gyjzG21052420
Citation:
WANG Zhiyuan, HU Zujun, LI Sheng, LI Suchao, LIU Zhenliang. SHAKING TABLE TESTS OF VERTICAL ISOLATION FOR TRANSFORMER MODELS BASED ON METALLIC RUBBER CUSHION AND SPRINGS[J]. INDUSTRIAL CONSTRUCTION, 2021, 51(11): 7-12. doi: 10.13204/j.gyjzG21052420
WANG Zhiyuan, HU Zujun, LI Sheng, LI Suchao, LIU Zhenliang. SHAKING TABLE TESTS OF VERTICAL ISOLATION FOR TRANSFORMER MODELS BASED ON METALLIC RUBBER CUSHION AND SPRINGS[J]. INDUSTRIAL CONSTRUCTION, 2021, 51(11): 7-12. doi: 10.13204/j.gyjzG21052420
Citation:
WANG Zhiyuan, HU Zujun, LI Sheng, LI Suchao, LIU Zhenliang. SHAKING TABLE TESTS OF VERTICAL ISOLATION FOR TRANSFORMER MODELS BASED ON METALLIC RUBBER CUSHION AND SPRINGS[J]. INDUSTRIAL CONSTRUCTION, 2021, 51(11): 7-12. doi: 10.13204/j.gyjzG21052420
1. Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education, School of Civil Engineering, Harbin Institute of Technology,Harbin 150090, China;
2. Department of Civil Engineering, Harbin Institute of Technology at Weihai,Weihai 264209, China;
3. China Electric Power Research Institute, Beijing 100055, China;
4. Institute of Architectural Engineering, Yancheng Kindergarten Teachers College, Yancheng 224005, China
Received Date: 2021-05-24 Available Online:
2022-03-29
In order to study the influence of wire diameters and nominal densities on the mechanical properties of metallic rubber(MR) cushions in different parameters and preloading conditions, and to verify whether the mechanical properties of metallic rubber cushious stable in preloading conditions, a three-dimensional(3 D) isolation device was proposed based on metallic rubber cushions and springs. Then, vertical isolation shaking table tests were conducted on a scaled isolated transformer model, and the dynamic characteristics of the isolated structure, as well as the vertical acceleration response of the structure under unidirectional or bidirectional input were measured. The results showed that the mechanical properties of metallic rubber under preloading were stable, and the vertical isolation device based on metallic rubber cushions and springs could effectively reduce the natural frequencies of structures and effectively reduce the energy input, and the isolation efficiency increased with the increment of the peak ground acceleration.
MUROTA N,FENG M Q,LIU G Y.Earthquake Simulator Testing of Base-Isolated Power Transformers[J].IEEE Transactions on Power Delivery,2006,21(3):1291-1299.
[4]
GÖKÇE T,YÜKSEL E O.Seismic Performance Enhancement of High-Voltage Post Insulators by a Polyurethane Spring Isolation Device[J].Bulletin of Earthquake Engineering:Official Publication of the European Association for Earthquake Enginee-ring,2019,17(3):1739-1762.
LEE D,CONSTANTINOU M C.Combined Horizontal-Vertical Seismic Isolation System for High-Voltage-Power Transformers:Development,Testing and Validation[J].Bulletin of Earthquake Engineering,2018,16(2):4273-4296.