XU Qian, WANG Jincheng, ZHANG Zhiqian, WANG Yongfeng, JIN Jing, LI Xiongyan, WEI Jingang, GENG Yan. Scheme Design of Health Monitoring on Operation Status for a Hot Water Energy Storage Tank and Engineering Practice[J]. INDUSTRIAL CONSTRUCTION, 2022, 52(2): 169-174,185. doi: 10.13204/j.gyjzG20121405
Citation: XU Qian, WANG Jincheng, ZHANG Zhiqian, WANG Yongfeng, JIN Jing, LI Xiongyan, WEI Jingang, GENG Yan. Scheme Design of Health Monitoring on Operation Status for a Hot Water Energy Storage Tank and Engineering Practice[J]. INDUSTRIAL CONSTRUCTION, 2022, 52(2): 169-174,185. doi: 10.13204/j.gyjzG20121405

Scheme Design of Health Monitoring on Operation Status for a Hot Water Energy Storage Tank and Engineering Practice

doi: 10.13204/j.gyjzG20121405
  • Received Date: 2020-12-14
    Available Online: 2022-06-30
  • Publish Date: 2022-02-20
  • As an indispensable storage structure for renewable energy, the safety of hot water storage tank is of great significance. In order to test the rationality of the tank design and the safety of the tank during operation, the field strain and temperature are collected. The design scheme of health monitoring is particularly important in the whole monitoring process. Based on the Tongliao hot water storage engery tank project, combined with the actual situation of the project, a reasonable monitoring scheme was designed, according to the data processing results, the stress distribution and temperature change of the tank wall along the height direction could be obtained, and the influence of temperature on the strain at the measuring point could be obtained. By comparing the measured stress values with the finite element simulation results, the correctness of the theoretical analysis and the rationality of the monitoring scheme were verified, and suggestions were put forward for the establishment of the numerical model of the non-anchored vertical storage tank.
  • loading
  • [1]
    秦冰,付林,江亿.利用系统热惯性的热电联产电力调峰[J].煤气与热力,2005(10):6-8.
    [2]
    ARTECONI A, HEWITT N J, POLONARA F. Domestic demand-side management (DSM):role of heat pumps and thermal energy storage (TES) systems[J]. Applied Thermal Engineering, 2013, 51(1/2):155-165.
    [3]
    NUYTTEN T, CLAESSENS B, PAREDIS K, et al. Flexibility of a combined heat and power system with thermal energy storage for district heating[J]. Applied Energy, 2013, 104:583-591.
    [4]
    张婷.分布式蓄热在集中供热系统中的应用研究[D].哈尔滨:哈尔滨工业大学,2017.
    [5]
    左正,贾会朝.浅谈振弦式应变计及其在混凝土工程应用中的问题[J].建材与装饰,2018(49):241-242.
    [6]
    张静.立式圆筒形立式圆筒形热水储能罐力学性能及隔震研究[D].北京:北京工业大学,2019.
    [7]
    基康仪器有限公司.BGK-4000型振弦式应变计安装使用手册[M].北京:北京基康科技有限公司,2008.
    [8]
    张永慧.浅谈振弦式应变计在北排河挡潮闸监测中的应用[J].河北工程技术高等专科学校学报,2016(2):23-25.
    [9]
    基康仪器有限公司.BGK-408振弦读数仪操作及通讯软件使用手册[M].北京:北京基康科技有限公司,2008.
    [10]
    廖威.新光大桥健康监测系统研究[D].广州:华南理工大学,2010.