YU Jinghai, ZHAO Siyu, YAN Mingting, LI Luchuan, YAN Xiangyu. FIRE RESISTANCE ANALYSIS OF CONCRETE-FILLED SQUARE STEEL TUBULAR COLUMNS[J]. INDUSTRIAL CONSTRUCTION, 2020, 50(5): 145-150,192. doi: 10.13204/j.gyjz202005024
Citation: YU Jinghai, ZHAO Siyu, YAN Mingting, LI Luchuan, YAN Xiangyu. FIRE RESISTANCE ANALYSIS OF CONCRETE-FILLED SQUARE STEEL TUBULAR COLUMNS[J]. INDUSTRIAL CONSTRUCTION, 2020, 50(5): 145-150,192. doi: 10.13204/j.gyjz202005024

FIRE RESISTANCE ANALYSIS OF CONCRETE-FILLED SQUARE STEEL TUBULAR COLUMNS

doi: 10.13204/j.gyjz202005024
  • Received Date: 2019-11-04
  • Publish Date: 2020-07-14
  • The finite element analysis model of concrete-filled square steel tubular (CFST) composite columns was established by using the sequential thermo-mechanical coupling analysis method and ABAQUS finite element software, and its reliability was verified by tests. On this basis, the factors affecting the fire resistance of concrete-filled square steel tubular columns were deeply analyzed. The results showed that the section area, load ratio, slenderness ratio and the thickness of fire protection layer of concrete were important factors affecting the mechanical properties of composite columns at high temperature. Under the effective fire protection, the composite column could bear greater axial force than the circular section and square section columns, the greater the load ratio, the lower the fire resistance limit of the composite column, the more significant the effect was when axial compression ratio n<0.5.
  • loading
  • LIE T T, CHABOT M. Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled with Plain Concrete:No.611[R]. Canada, Ottawa Ont:NRC-CNRC Internal Report, 1992.
    CHABOT M, LIE T T. Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled with Bar-Reinforced Concrete:No.628[R]. Canada, Ottawa Ont:NRC-CNRC Internal Report, 1992.
    LIE T T, DENHAM E M A. Factors Affecting the Fire Resistance of Circular Hollow Steel Columns Filled with Bar-Reinforced Concrete:No.651[R].Canada, Ottawa Ont:NRC-CNRC Internet Report, 1993.
    KODUR V K R, LIE T T. Experimental Studies on the Fire Resistance of Circular Hollow Steel Columns Filled with Steel-Fire-Reinforced Concrete:No.691[R]. Canada, Ottawa Ont:NRC-CNRC Internet Report, 1995.
    KODUR V K R, LIE T T. Experimental Studies on the Fire Resistance of Square Hollow Steel Columns Filled with Steel-Fire-Reinforced Concrete:No.662[R]. Canada, Ottawa Ont:NRC-CNRC Internet Report, 1996.
    LIE T T, CARGON S E. Fire Resistance of Hollow Steel Columns Filled with Siliceous Aggregate Concrete:Test Results:No.573[R]. Canada, Ottawa Ont:NRC-CVRC Internal Report, 1988.
    KODUR V K R, LATOUR J C. Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled with High-Strength Concrete:No.215[R]. Canada, Ottawa Ont:NRC-CNRC Research Report, 2005.
    KODUR V K R. Solutions for Enhancing the Fire Endurance of HSS Columns Filled with High-Strength Concrete[J]. AISC Engineering Journal, 2006, 43(1):1-7.
    SAKUMOTO Y, OKADA T, YOSHIDA M, et al. Fire Resistance of Concrete-Filled, Fire-Resistant Steel-Tube Columns[J]. Journal of Materials in Civil Engineering, 1994, 6(2):169-184.
    LU H, ZHAO X L, HAN L H. Fire Behavior of High Strength Self-Consolidating Concrete Filled Steel Tubular Stub Columns[J]. Journal of Constructional Steel Research, 2009, 65(10):1995-2010.
    HAN L H, ZHAO X L, YANG Y F, et al. Experimental Study and Calculation of Fire Resistance of Concrete-Filled Hollow Steel Columns[J]. Journal of Structural Engineering, 2003, 129(3):346-356.
    韩林海, 贺军利. 钢管混凝土柱耐火性的试验研究[J]. 土木工程学报, 2000, 33(3):31-35.
    韩林海,徐蕾. 带保护层方钢管混凝土柱耐火极限的试验研究[J]. 土木工程学报, 2000(6):63-69.
    LIE T T. Fire Resistance of Circular Steel Columns Filled with Bar-Reinforced Concrete[J]. Journal of Structural Engineering, ASCE, 1994, 120(5):1489-1509.
    时旭东. 高温下钢筋混凝土杆系结构试验研究和非线性有限元分析[D]. 北京:清华大学, 1992.
    韩林海. 钢管混凝土结构:理论与实践[M]. 北京:科学出版社, 2007.
    徐蕾. 方钢管混凝土柱耐火性能及抗火设计方法研究[D]. 哈尔滨:哈尔滨工业大学,2002.
    赵炳震. 方钢管混凝土组合异形柱框架-支撑结构体系力学性能研究[D]. 天津:天津大学, 2017.
    中华人民共和国住房和城乡建设部.建筑设计防火规范:GB 50016-2014[S].北京:中国计划出版社,2015.
  • 加载中