Source Journal for Chinese Scientific and Technical Papers
Core Journal of RCCSE
Included in JST China
Included in the Hierarchical Directory of High-quality Technical Journals in Architecture Science Field
Volume 50 Issue 2
Feb.  2020
Turn off MathJax
Article Contents
BAI Zhengxian, GAO Jiawei, LIU Xuechun, ZHANG Dongjie, DENG Yuping, QIANG Shen, BAI Yaritu. RESEARCH ON THE CONNECTION PERFORMANCE OF GLASSFIBER REINFORCED PLASTICS CONNECTOR OF SANDWICH WALL[J]. INDUSTRIAL CONSTRUCTION, 2020, 50(2): 169-176,183. doi: 10.13204/j.gyjz202002026
Citation: BAI Zhengxian, GAO Jiawei, LIU Xuechun, ZHANG Dongjie, DENG Yuping, QIANG Shen, BAI Yaritu. RESEARCH ON THE CONNECTION PERFORMANCE OF GLASSFIBER REINFORCED PLASTICS CONNECTOR OF SANDWICH WALL[J]. INDUSTRIAL CONSTRUCTION, 2020, 50(2): 169-176,183. doi: 10.13204/j.gyjz202002026

RESEARCH ON THE CONNECTION PERFORMANCE OF GLASSFIBER REINFORCED PLASTICS CONNECTOR OF SANDWICH WALL

doi: 10.13204/j.gyjz202002026
  • Received Date: 2019-09-03
  • The prefabricated sandwich wall is a new type of wall, which integrates load-bearing, heat preservation and light weight. It consists of inner and outer leaf walls, connector and intermediate insulation board. The connector is a key component for connecting the inner and outer leaf walls and the thermal insulation boards. The current connector on the market are mostly imported from abroad, and the price is very high, it is not conducive to be widely used. Therefore, it is necessary to find a new type of connector with good mechanical properties, thermal insulation performance and low price. In the paper, glass fiber reinforced plastics profile was selected as the material of connector for the sandwich wall. Compared with the conventional connector, it showed the advantages of no cold and heat bridge, high strength, excellent corrosion resistance and low price. The pull-out and shear tests on the prefabricated sandwich wall with different types and sizes of fiberglass reinforced plastics were peformed, including rods, plates, L-section, H-section and C-section profiles. The thermal test of the sandwich wall was also carried out. The results showed that the glass fiber reinforced plastics had good shear and tensile strength as well as thermal insulation performance. The C-section connector had the largest crack-resisting load and ultimate load, which might be more suitable for the inner connector of prefabricated sandwich walls.
  • loading
  • 杭迎伟.复合保温围护墙板工业化成套技术研究与应用[R].上海:上海建工(集团)总公司,2010
    WU G, WANG X, WU Z, et al. Durability of Basalt Fibers and Composites in Corrosive Environments[J]. Journal of Composite Materials, 2015, 49(7):873-887.
    LIU R N, ZHANG K Y, TAO M L. Comparison Study on Thermal Performance of the RC Sandwich Panels with Different Connectors[C]//Applied Mechanics and Materials. Trans Tech Publications, 2013, 253:674-678.
    刘若南. 基于强度的预制混凝土夹芯保温墙板连接件设计研究[D].武汉:武汉理工大学,2014.
    CHOI K B, CHOI W C, FEO L, et al. In-Plane Shear Behavior of Insulated Precast Concrete Sandwich Panels Reinforced with Corrugated GFRP Shear Connectors[J]. Composites Part B:Engineering, 2015, 79:419-429.
    CHOI W, JANG S J, YUN H D. Design Properties of Insulated Precast Concrete Sandwich Panels with Composite Shear Connectors[J]. Composites Part B:Engineering, 2019, 157:36-42.
    ZHI Q, GUO Z. Experimental Evaluation of Precast Concrete Sandwich Wall Panels with Steel-Glass Fiber-Reinforced Polymer Shear Connectors[J]. Advances in Structural Engineering, 2017, 20(10):1476-1492.
    NAITO C, HOEMANN J, BEACRAFT M, et al. Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels[J]. Journal of Structural Engineering, 2011, 138(1):52-61.
    孟宪宏,周阿龙,刘海成.夹芯保温外墙板连接件力学性能试验[J].沈阳建筑大学学报,2014,30(2):232-233.
    张延年,李恒,刘明,等.新型夹心墙用耐腐蚀拉结件受力性能试验[J].沈阳工业大学学报,2010,32(2):228-234.
    HUANG J Q, DAI J G. Direct Shear Tests of Glass Fiber Reinforced Polymer Connectors for Use in Precast Concrete Sandwich Panels[J]. Composite Structures, 2019, 207:136-147.
    JIANG H, GUO Z, LIU J, et al. The Shear Behavior of Precast Concrete Sandwich Panels with W-Shaped SGFRP Shear Connectors[J]. KSCE Journal of Civil Engineering, 2018, 22(10):3961-3971.
    YUN H D, JANG S J, YOU Y C. Direct Shear Responses of Insulated Concrete Sandwich Panels with GFRP Shear Connectors[C]//Applied Mechanics and Materials. Trans Tech Publications, 2012:803-806.
    WOLTMAN G,TOMLINSON D,FAM A.Investigation of Various GFRP Shear Connectors for lnsulated Precast Concrete Sandwich Wall Panels[J]. Journal of Composites for Construction,2013,17(5):711-721.
    薛伟辰,杨佳林,王君若.预制夹芯保温墙体FRP连接件抗拔性能试验研究[J].玻璃钢/复合材料,2012(4):55-59.
    杨佳林,薛伟辰,栗新.预制夹芯保温墙体FRP连接件的力学性能试验[J].江苏大学学报(自然科学版),2013,34(6):723-729.
    薛伟辰,付凯,秦珩.预制夹芯保温墙体FRP连接件抗拉强度加速老化试验研究[J].建筑材料学报,2014,17(3):422-423.
    薛伟辰,付凯,李向民. 预制夹芯保温墙体FRP连接件抗剪性能加速老化试验研究[J].建筑结构,2012,42(7):107-108.
    姜伟庆,张芸,秦桁,等. 预制夹心保温墙体新型FRP连接件抗拔性能[C]//第八届全国建设工程FRP应用学术交流会论文集.北京:2013:4.
    王晓璐,查晓雄.高温下GFRP筋力学性能的试验研究[J].华南理工大学学报,2011,39(9):77-80.
    翟希梅,王雪明. 预制混凝土夹芯墙连接件拉拔性能试验研究[J]. 武汉大学学报(工学版),2015,48(增刊):78-84.
    翟希梅,王雪明.预制夹芯墙体中新型复合式连接件受力性能试验研究[J].建筑结构,2018,48(7):73-78.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (71) PDF downloads(2) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return