Source Journal for Chinese Scientific and Technical Papers
Core Journal of RCCSE
Included in JST China
Included in the Hierarchical Directory of High-quality Technical Journals in Architecture Science Field
Volume 45 Issue 10
Dec.  2015
Turn off MathJax
Article Contents
Shu Xingping Mao Jiaxi Yuan Zhishen Lu Beirong, . THE EVALUATION OF CAPACITY TO RESIST PROGRESSIVE COLLAPSE OF PREFABRICATED STEEL FRAME STRUCTURE WITH INCLINED SUPPORT JOINTS[J]. INDUSTRIAL CONSTRUCTION, 2015, 45(10): 13-17. doi: 10.13204/j.gyjz201510003
Citation: Shu Xingping Mao Jiaxi Yuan Zhishen Lu Beirong, . THE EVALUATION OF CAPACITY TO RESIST PROGRESSIVE COLLAPSE OF PREFABRICATED STEEL FRAME STRUCTURE WITH INCLINED SUPPORT JOINTS[J]. INDUSTRIAL CONSTRUCTION, 2015, 45(10): 13-17. doi: 10.13204/j.gyjz201510003

THE EVALUATION OF CAPACITY TO RESIST PROGRESSIVE COLLAPSE OF PREFABRICATED STEEL FRAME STRUCTURE WITH INCLINED SUPPORT JOINTS

doi: 10.13204/j.gyjz201510003
  • Publish Date: 2015-10-20
  • There are no unified assessment standards of progressive collapse due to the complex mechanism of progressive collapse both at home and abroad so far. The adaptability of the evaluation index of antiprogressive collapse capacity specified by Guidelines for Collapse Control Design of Steel Structures with High Redundancy of Japan to the prefabricated steel frame structures with inclined support joints was verified by 3 examples of 4-span and 5-story prefabricated steel frame structures with inclined support joints. Based on the subject of a nine-story prefabricated steel frame structure with inclined support joints,corner column,short side middle column,long side middle column and inside middle column were removed with the alternative load path method,the performance evaluation of antiprogressive collapse was conducted with performance evaluation method raised above,the result showed that structures performance of resisting progressive collapse turned out to be able to meet the need,the structures antiprogressive collapse performance after removing corner column was much better than that of removing inner column. In addition,the safety margin of trussed beam was lower than that of the column.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (119) PDF downloads(176) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return