Citation: | Zhang Junfeng, Ge Yaojun, Zhao Lin. INTRODUCTIONS AND ANALYSES OF COLLAPSE OF COOLING TOWER FOR FERRYBRIDGE POWER STATION[J]. INDUSTRIAL CONSTRUCTION, 2013, 43(2): 153-158. doi: 10.13204/j.gyjz201302031 |
[2] Pope R A. Structural Deficiencies of Natural Draught CoolingTowers at UK Power Stations. Part 2:Surveying and structuralappraisal[J]. Proceedings of the ICE-Structures and Buildings,1994,104(1):11-23.
|
Pope R A. Structural Deficiencies of Natural Draught CoolingTowers at UK Power Stations. Part 1:Failures at Ferrybridge andFiddlers Ferry[J]. Proceedings of the ICE-Structures andBuildings,1994,104(1):1-10.
|
[3] Pope R A. Structural Deficiencies of Natural Draught CoolingTowers at UK Power Stations. Part 3:Strengthening of Natural Draught Cooling Tower Shells[J]. Proceedings of the ICEStructures and Buildings,1994,104(1):25-37.
|
[4] Bosman P B, Strickland I G, Prukl R P. Strengthening of NaturalDraught Cooling Tower Shells with Stiffening Rings[J].Engineering Structures,1998,20(10):909-914.
|
[5] Bamu P C, Zingoni A. Damage, Deterioration and the Long-TermStructural Performance of Cooling-Tower Shells: a Survey ofDevelopments over the Past 50 Years[J]. Engineering Structures,2005,27(12):1794-1800.
|
[6] Neil S. When Technology Fails[M]. London: Gale ResearchInc,1994:267-270.
|
[7] Central Electricity Generating. Board Report of the COI intoCollapse of Cooling Towers at Ferrybridge, Monday 1 November1965[R]. London: Central Electricity Generating Board,1966.
|
[8] NDCT 1 st. Proceedings of the First International Symposium onNatural Draught Cooling Towers-Ferrybridge and After[C]∥England, London:1967.
|
[9] Improved Construction of Cooling Towers of Reinforced Concrete[S]. Patent Specification, No.108863, United Kingdom,1918.
|
[10] Damjakob H, Tummers N. Back to the Future of the HyperbolicConcrete Tower[C]∥ Proceedings of the Fifth InternationalSymposium on Natural Draught Cooling Towers. Istanbul, Turkey:2004:3-21.
|
[11] Bosman P B. Review and Feedback of Experience of Gained Overthe Last Fifty Years in Design and Construction of Natural DraughtCooling Towers[J]. Engineering Structures,1985,7(4):268-272.
|
[12] 张军锋,葛耀君.现行规范中双曲壳体冷却塔静风局部稳定公式来源[J].建筑结构,2011,41(3):100-109.
|
[13] Armitt J. Wind Loading on Cooling Towers[J]. Journal of theStructural Division, ASCE,1980,106(3):623-641.
|
[14] Niemann H J, Kpper H D. Influence of Adjacent Buildings onWind Effects on Cooling Towers[J]. Engineering Structures,1998,20(10):874-880.
|
[15] Davenport A G, Isyumov N. The Application of the BoundaryLayer Wind Tunnel to the Prediction of Wind Loading[C]∥International Research Seminar on Wind Effects on Buildings andStructures. Ottawa, Canada: University of Toronto Press,1968.
|
[16] Smith A O, Pope R A, Bierrum N R. A Revised UK Standard forCooling Towers (BS 4485 part 4)[C]∥ Proceedings of the ForthInternational Symposium on Natural Draught Cooling Towers,Kaiserslautern, Germany:1996,321-328.
|
[17] 王宁博,沈国辉,楼文娟,等.再议渡桥电厂冷却塔的倒塌原因倒塌事故中的塔型因素分析[C]∥第十五届全国结构风工程学术会议论文集.杭州:2011:250-253.
|
[18] Jullien J F, Reynouard J M. Reflections on the Origin ofDeflections Observed on the Cooling Towers of Pont Sur Sambreand Ansereuilles[C]∥ Proceedings of the Third InternationalSymposium on Natural Draught Cooling Towers. France, Pairs:1989:595-604.
|
[19] Krivoshapko S N. Static, Vibration, and Buckling Analyses andApplications to One-Sheet Hyperboloidal Shells of Revolution[J].Applied Mechanics Reviews,2002,55(3):241-270.
|
[20] Wittek U. A First Step to a Documentation of the StructuralHeritage of RC Cooling Towers[C]∥ Proceedings of the FifthInternational Symposium on Natural Draught Cooling Towers.Istanbul, Turkey:2004:31-34.
|