Zhou Ming, Wang Xintang, Wang Wanzhen. EXPERIMENTAL STUDY ON BEARING CAPACITY AND MECHANICAL BEHAVIOR OF THE CERAMSITE CONCRETE FILLED STEEL TUBULAR SHORT COLUMNS AFTER FIRE[J]. INDUSTRIAL CONSTRUCTION, 2013, 43(1): 99-103,111. doi: 10.13204/j.gyjz201301022
Citation: Zhou Ming, Wang Xintang, Wang Wanzhen. EXPERIMENTAL STUDY ON BEARING CAPACITY AND MECHANICAL BEHAVIOR OF THE CERAMSITE CONCRETE FILLED STEEL TUBULAR SHORT COLUMNS AFTER FIRE[J]. INDUSTRIAL CONSTRUCTION, 2013, 43(1): 99-103,111. doi: 10.13204/j.gyjz201301022

EXPERIMENTAL STUDY ON BEARING CAPACITY AND MECHANICAL BEHAVIOR OF THE CERAMSITE CONCRETE FILLED STEEL TUBULAR SHORT COLUMNS AFTER FIRE

doi: 10.13204/j.gyjz201301022
  • Received Date: 2012-04-25
  • Publish Date: 2013-01-20
  • The experimental investigation on post-fire mechanical behavior of ten of four sets of unprotected short columns of ceramsite concrete filled steel tubes(CCFST) was conducted,variation of remaining bearing capacity and failure form of the short columns of CCFST after exposure to fire was discussed for different parameters.Based on the test results,effect of the factors,such as the maximum value of fire temperatures,dimension of cross section of the specimen,slender ratio and concrete mix proportion on the remaining bearing capacities and ductility of CCFST short columns were especially investigated.The results showed that the CCFST short columns after exposure to fire had higher post-fire bearing capacity and better ductility,and there was no descent segment in load-displacement curves of the most of specimens.It was concluded that effect law of the maximum values of response temperature on bearing capacities of CCFST short columns after exposure to fire were related to some key parameters of the specimens,which were mix proportion,slender ratio and dimension of cross section of the specimens.It was shown that the post-fire bearing capacities of the CCFST short columns decreased with increase of water cement ratios of the concrete of the specimens subjected to fire load.
  • loading
  • [2] 韩林海,霍静思.火灾作用后钢管混凝土柱的承载力研究[J].土木工程学报,2002,35(4):25-35.
    韩林海,贺军利,吴海江,等.圆形截面钢管混凝土柱耐火性能的试验研究[J].土木工程学报,2000,33(3):31-36.
    [3] Lie T,Chabot M. Evaluation of the Fire Resistance ofCompression Members Using Mathematical Models[J]. Fire SafetyJournal,1993,20(2):135-149.
    [4] Lie T T. Fire Resistance of Circular Steel Columns Filled with BarReinforced Concrete[J]. Journal of Structural Engineering,1994,120(5):1489-1509.
    [5] Kodur V K R. Performance-Based Fire Resistance Design ofConcrete-Filled Steel Columns[J]. Journal of Constructional SteelResearch,1999,51(1):21-26.
    [6] Tao Zhong,Han Linhai,Wang Lingling. Compressive andFlexural Behaviour of CFRP-Repaired Concrete-Filled Steel TubesAfter Exposure to Fire [J]. Journal of Constructional SteelResearch,2007,63(8):1116-1126.
    [7] 韦灼彬,刘锡良.钢管陶粒混凝土在网架结构上的应用[J].钢结构,1994(3):211-214.
    [8] Zhou Ming,Wang Xintang,Wang Haijiang. Experimental Studyon Axially Loaded Behavior of Short Columns of CeramsiteConcrete Filled Steel Tube After Fire[C]//Pacific Structural SteelCongerence. Beijing:2010:1638-1643.