Wu Tao, Xing Guohua, Liu Boquan. ANALYSIS OF EFFECT FACTOR ON SEISMIC BEHAVIOR OF ABNORMAL INTERIOR JOINTS IN REINFORCED CONCRETE FRAME STRUCTURES[J]. INDUSTRIAL CONSTRUCTION, 2009, 39(10): 30-34. doi: 10.13204/j.gyjz200910010
Citation:
Wu Tao, Xing Guohua, Liu Boquan. ANALYSIS OF EFFECT FACTOR ON SEISMIC BEHAVIOR OF ABNORMAL INTERIOR JOINTS IN REINFORCED CONCRETE FRAME STRUCTURES[J]. INDUSTRIAL CONSTRUCTION , 2009, 39(10): 30-34. doi: 10.13204/j.gyjz200910010
Wu Tao, Xing Guohua, Liu Boquan. ANALYSIS OF EFFECT FACTOR ON SEISMIC BEHAVIOR OF ABNORMAL INTERIOR JOINTS IN REINFORCED CONCRETE FRAME STRUCTURES[J]. INDUSTRIAL CONSTRUCTION, 2009, 39(10): 30-34. doi: 10.13204/j.gyjz200910010
Citation:
Wu Tao, Xing Guohua, Liu Boquan. ANALYSIS OF EFFECT FACTOR ON SEISMIC BEHAVIOR OF ABNORMAL INTERIOR JOINTS IN REINFORCED CONCRETE FRAME STRUCTURES[J]. INDUSTRIAL CONSTRUCTION , 2009, 39(10): 30-34. doi: 10.13204/j.gyjz200910010
ANALYSIS OF EFFECT FACTOR ON SEISMIC BEHAVIOR OF ABNORMAL INTERIOR JOINTS IN REINFORCED CONCRETE FRAME STRUCTURES
Received Date: 2009-02-28
Publish Date:
2009-10-20
Abstract
Six specimens of abnormal interior joints were tested under reversed cyclic loading.Experimental studies were carried out to investigate the effect of joint core dimensions and axial compression ratio on seismic behaviour of abnormal joints.Test results indicated that column section abrupt had little effect on seismic behavior of the specimen.When the reduced height of column section was less than 1/6 column section height,that is h_ch_c/6,the negative effect of that could be neglected.The test results also indicated that beam section abrupt had an obvious effect on seismic behavior of the beam-column subassemblage. When h_b was between h_c/6 and 2h_(bl)/5,the seismic behavior improved gradually with the increase of h_b;When h_b was between 2h_(bl)/5 and h_(bl)/2,the seismic behavior deteriorated with the increase of h_b;When h_b was greater than 1/2 high beam section depth,a exterior joint model would be better for this case analysis.In addition,the axial load level of the column had a negative effect on seismic behavior of abnormal joints after the beam-column subassemblage reached to critical crack stage,it was suggested that the axial compression ratio shoulds be less than 0.3 for the seismic design of this sort of abnormal joint.
References
GB500102002混凝土结构设计规范[S].
[2] GB500112001建筑抗震设计规范[S].
[3] 吴涛,刘伯权,白国良,等.大型厂房钢筋混凝土框排架结构中异型节点的抗震性能和设计方法研究[J].土木工程学报,2006,39(4):1-5.
[4] 框架节点专题研究组.低周反复荷载作用下钢筋混凝土框架梁柱节点核心区抗剪强度的试验研究[J].建筑结构学报,1983,4(6):1-17.
[5] 唐九如.钢筋混凝土框架节点抗震[M].南京:东南大学出版社,1989:31-32.
Relative Articles
[1] SU Sanqing, HAN Song, WANG Wei, LI Yu, JIANG Hao. ANALYTICAL STUDY OF THE BEARING CAPACITY FOR DOWEL-TYPE CONNECTIONS IN GLUED TIMBER WITH SLOTTED STEEL PLATES BASED ON THE BEAM ON ELASTIC FOUNDATION [J]. INDUSTRIAL CONSTRUCTION, 2021, 51(9): 143-149. doi: 10.13204/j.gyjzG20121417
[3] Shen Jiajia, Tong Genshu, Deng Hua. STUDY ON SOME KEY PROBLEMS RELATED TO CRANE BEAM-RAIL SYSTEM UNDER WHEEL PRESSURE [J]. INDUSTRIAL CONSTRUCTION, 2014, 44(10): 132-139. doi: 10.13204/j.gyjz201410027
[4] Pang Naiyong, Jia Yingjie, Xia Lei. ANALYSIS OF FACTORS INFLUENCING PERFORMANCE OF FRAME-SUPPORTED MULTI-RIBBED WALL BEAM UNDER VERTICAL LOAD [J]. INDUSTRIAL CONSTRUCTION, 2012, 42(2): 54-57. doi: 10.13204/j.gyjz201202012
[5] Liu Hongyan, Li Houen, Huang Yushi, LüShuran. DISPLACEMENT CALCULATION OF NEARBY UNDERGROUND PIPELINE CAUSED BY DEEP EXCAVATION BASED ON FIELD TEST OF GROUND DISPLACEMENT [J]. INDUSTRIAL CONSTRUCTION, 2011, 41(10): 72-74,94. doi: 10.13204/j.gyjz201110018
[6] Wang Zanzhi, Jiang Linyan, Xin Lifeng, Tian Yi, Li Xingyao, Huang Shibin, Tang Xianyuan, Hu Xizhang. FREE VIBRATION ANALYSIS OF THE BEAM INTERACTION WITH THE VISCOELASTIC FOUNDATION [J]. INDUSTRIAL CONSTRUCTION, 2009, 39(10): 57-61. doi: 10.13204/j.gyjz200910015
[7] Yao Qianfeng, Jing Gang, Huang Wei, Chen Guoxin. STUDY ON RIGID FRAME-EQUIVALENT BRACE MODEL OF MULTI-RIBBED SLAB STRUCTURE [J]. INDUSTRIAL CONSTRUCTION, 2009, 39(8): 52-56,51. doi: 10.13204/j.gyjz200908014
[8] Fan Dewei, Li Dayong, Zhang Xuechen. ANALYSIS OF VERTICAL DISPLACEMENT AND INNER FORCES IN BURIED PIPELINES CAUSED BY METRO TUNNELING [J]. INDUSTRIAL CONSTRUCTION, 2009, 39(9): 85-89. doi: 10.13204/j.gyjz200909018
[9] Ding Yonggang, Jia Yingjie, Yuan Quan, Yao Qianfeng. ANALYSIS OF THE INTERNAL FORCE COEFFICIENT OF THE TRIMMER BEAM OF TWO-SPAN FRAME-SUPPORTED MULTI-RIBBED WALL BEAM [J]. INDUSTRIAL CONSTRUCTION, 2008, 38(9): 59-63,121. doi: 10.13204/j.gyjz200809018
Proportional views
Created with Highcharts 5.0.7 Amount of access Chart context menu Abstract Views, HTML Views, PDF Downloads Statistics Abstract Views HTML Views PDF Downloads 2024-05 2024-06 2024-07 2024-08 2024-09 2024-10 2024-11 2024-12 2025-01 2025-02 2025-03 2025-04 0 2.5 5 7.5 10 12.5 15
Created with Highcharts 5.0.7 Chart context menu Access Class Distribution FULLTEXT : 23.9 % FULLTEXT : 23.9 % META : 76.1 % META : 76.1 % FULLTEXT META
Created with Highcharts 5.0.7 Chart context menu Access Area Distribution 其他 : 42.4 % 其他 : 42.4 % Central District : 6.5 % Central District : 6.5 % China : 3.3 % China : 3.3 % 上海 : 1.1 % 上海 : 1.1 % 北京 : 5.4 % 北京 : 5.4 % 南平 : 1.1 % 南平 : 1.1 % 台州 : 1.1 % 台州 : 1.1 % 张家口 : 8.7 % 张家口 : 8.7 % 日照 : 1.1 % 日照 : 1.1 % 淮北 : 1.1 % 淮北 : 1.1 % 湖州 : 1.1 % 湖州 : 1.1 % 芒廷维尤 : 15.2 % 芒廷维尤 : 15.2 % 衢州 : 3.3 % 衢州 : 3.3 % 西宁 : 4.3 % 西宁 : 4.3 % 重庆 : 1.1 % 重庆 : 1.1 % 阳泉 : 3.3 % 阳泉 : 3.3 % 其他 Central District China 上海 北京 南平 台州 张家口 日照 淮北 湖州 芒廷维尤 衢州 西宁 重庆 阳泉