Turn off MathJax
Article Contents
Wang Chungang, Zhang Yaochun. AXIALLY LOADED CARRYING CAPACITY CALCULATION OF THIN-WALLED COLD-FORMED CHANNEL COLUMNS WITH INCLINED SIMPLE EDGE STIFFENERS BY DIRECT STRENGTH METHOD[J]. INDUSTRIAL CONSTRUCTION, 2006, 36(1): 71-74. doi: 10.13204/j.gyjz200601021
Citation: Wang Chungang, Zhang Yaochun. AXIALLY LOADED CARRYING CAPACITY CALCULATION OF THIN-WALLED COLD-FORMED CHANNEL COLUMNS WITH INCLINED SIMPLE EDGE STIFFENERS BY DIRECT STRENGTH METHOD[J]. INDUSTRIAL CONSTRUCTION, 2006, 36(1): 71-74. doi: 10.13204/j.gyjz200601021

AXIALLY LOADED CARRYING CAPACITY CALCULATION OF THIN-WALLED COLD-FORMED CHANNEL COLUMNS WITH INCLINED SIMPLE EDGE STIFFENERS BY DIRECT STRENGTH METHOD

doi: 10.13204/j.gyjz200601021
  • Received Date: 2005-08-20
  • Publish Date: 2006-01-20
  • Section geometric properties of channels with different bending degrees of inclined simple edge stiffeners are gained by calculation. It is convenient for solving the buckling stress by hand. The test strengths and failure modes reported by an experimental reference of axially loaded fixed-ended channels with inclined simple edge stiffeners are compared with the strengths predicted using direct strength method. It is shown that direct strength method is valid for predicting the stability capacity of axially loaded fixed-ended channel columns with inclined simple edge stiffeners, consequently it is indicated that direct strength method which was developed based on the regression of pin-ended tests results is also applicable for calculating the stability capacity of fixed-ended columns.
  • loading
  • [2] Young B,Yan J.Design of Cold-Formed Steel Channel Columns with Complex Edge Stiffeners by Direct Strength Method.J.Struct.Eng.,2004,130(11):1 756-1 763
    Schafer B W,Pekz T.Direct Strength Prediction of Cold-Formed Steel Members Using Numerical Elastic Buckling Solutions∥ Second International Conference on Thin-Walled Structures:Thin-Walled Structures Research and Development.Singapore:Elsevier Science Ltd,1998:137-144
    [3] Young B,Hancock G J.Compression Tests of Channels with Inclined Simple Edge Stiffeners.J.Struct.Eng.,2003,129(10):1 403-1 411
    [4] BS5950.Part 5.Structural Use of Steelwork in Building.Code of Practice for Design of Cold Formed Thin Gauge Sections.2000
    [5] Schafer B W,Pekz T.Laterally Braced Cold-Formed Steel Flexural Members with Edge Stiffened Flanges.J.Struct.Eng.,1999,125(2):118-127
    [6] Lau S C W,Hancock G J.Distortional Buckling Formulas for Channel Columns.J.Struct.Eng.,1987,113(5):1 063-1 078
    [7] Schafer B W.Local,Distortional and Euler Buckling of Thin-Walled Columns.J.Struct.Eng.,2002,128(3):289-299
    [8] 陈骥.钢结构稳定--理论与设计.北京:科学出版社,2003:256-273
    [9] 郭在田.薄壁杆件的弯曲与扭转.北京:中国建筑工业出版社,1989:374-378
    [10] 0 Hancock G J,Murray T M,Ellifritt D S.Cold-Formed Steel Structures to the AISI Specification.New York:Marcel Dekker,Inc.,2001:357-392