Turn off MathJax
Article Contents
Yi Weijian, Zhao Xin. DAMAGE PATTERN OF COLUMNS WITH CORRODED STEEL BARS IN THE COMPRESSIVE ZONE OF CONCRETE SECTION AND THE DIFFICULT IDENTIFICATION OF CORROSION WITH HALF-CELL TECHNIQUE[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(12): 23-26,90. doi: 10.13204/j.gyjz200512007
Citation: Yi Weijian, Zhao Xin. DAMAGE PATTERN OF COLUMNS WITH CORRODED STEEL BARS IN THE COMPRESSIVE ZONE OF CONCRETE SECTION AND THE DIFFICULT IDENTIFICATION OF CORROSION WITH HALF-CELL TECHNIQUE[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(12): 23-26,90. doi: 10.13204/j.gyjz200512007

DAMAGE PATTERN OF COLUMNS WITH CORRODED STEEL BARS IN THE COMPRESSIVE ZONE OF CONCRETE SECTION AND THE DIFFICULT IDENTIFICATION OF CORROSION WITH HALF-CELL TECHNIQUE

doi: 10.13204/j.gyjz200512007
  • Received Date: 2005-05-30
  • Publish Date: 2005-12-20
  • It is presented an investigation of many reinforced concrete columns in four large workshops, since most of the columns are badly corroded.And a discussion of the usage of half-cell technique is carried out to get a fast appraisal of the corrosion state in the concrete structure, and is pointed out the limitation of the identification standard:ASTM C876.Based on the results of this investigation of corrosion damage and finite element method, it is also analyzed this kind of effect when the corrosion of the steel bars occurs in the compressive zone of concrete section of the reinforced concrete column.Even though there are the expanded action of corrosion products, it is clear that the location of stress peak point in the concrete, surrounding the corrosion bar is almost the same.But the compression stress could accelerate the development of corrosion crack obviously, which would speed up the failure of concrete cover.Moreover, corner spalling, and splitting spalling are two more potential models of the concrete cover failure.
  • loading
  • Bazant Z P.Physical for Steel Corrosion in Concrete Sea Structures--Application.Journal of Structural Division,1979,105(6):1 155-1 166
    [2] 洪定海.华南海港钢筋混凝土码头修饰调查报告.水运工程,1982(2)
    [3] 颜桂云,孙炳焰,王泽军,等.锈蚀钢筋混凝土压弯构件抗震性能的试验研究.建筑结构,2003,33(2):16-18
    [4] 龚晓南.工程安全及耐久性.见:中国土木工程学会第九届年会论文集.北京:中国水利水电出版社,2000
    [5] 金伟良,赵羽习.混凝土结构耐久性.北京:科学出版社,2002.92-104
    [6] 洪定海.混凝土中钢筋的腐蚀与保护.北京:中国铁道出版社,1998.14-80
    [7] 吴瑾,吴胜兴,和平.锈蚀钢筋混凝土保护层破坏模式.混凝土,2002(8):19-20
    [8] 王小惠,刘西拉.受荷锈蚀钢筋混凝土构件保护层纵向开裂时钢筋诱蚀深度的分析计算.混凝土与水泥制品,2003(4):47-49
    [9] 张喜德,韦树英,彭修宁.钢筋锈蚀对混凝土抗压强度影响的试验研究.工业建筑,2003,33(3):5-7
    [10] Wallbank E J.The Performance of Concrete in Bridges--A Survey of 200 Highway Bridges.1989.22-37
    [11] Broomfield J P.The Determination of Rate of Highway Bridge Deterioration,Rehabilitation and Life Cycle Costing under Strategic Highway Research Program ln:NACE Symposium.Cambridge,1991.14