Sun Bingnan, LüChaokun, Mao Guodong. STMD CONTROL FOR SEISMIC RESPONSE OF TALL BUILDING[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(7): 39-42. doi: 10.13204/j.gyjz200507012
Citation: Sun Bingnan, LüChaokun, Mao Guodong. STMD CONTROL FOR SEISMIC RESPONSE OF TALL BUILDING[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(7): 39-42. doi: 10.13204/j.gyjz200507012

STMD CONTROL FOR SEISMIC RESPONSE OF TALL BUILDING

doi: 10.13204/j.gyjz200507012
  • Received Date: 2004-07-15
  • Publish Date: 2005-07-20
  • In order to control the seismic response of the tall building and eliminate the / time lag0 phenomenon by actuation of the control mechanism, intelligent TMD is proposed which consists ofMR dampers. The change of yield stress of MR fluids is in the same way of magnetic field. So the controlling force of the intelligent TMD can be adjusted by changing magnetic field. According to instantaneouw optimum control principle, we use the improved sem-i active control strategy which derived from the Hrovat and on- off control strategy to analyse the parameters of the MR dampers. An eight storied frame structure is analysed. From the numerical analysis, we can see the dvice could diminish the seismic response of a tall structure.
  • loading
  • [2] Housner G W. Structural Control:Past, Present, and Future. ASCE, J. Engrg. Mech,1997,123(9):897~958
    周福霖.工程结构减震控制.北京:地震出版社,1997
    [3] 李忠献,张伟,姜忻良,等.高层建筑地震反应全反馈主动TMD控制理论研究.地震工程与工程振动,1997(9):60~65
    [4] 隋莉莉,欧进萍.半主动磁流变减振驱动器的工作原理及应用.哈尔滨建筑大学学报,2002(6):9~19
    [5] 瞿伟廉,王军武,徐幼麟,等.ER/MR智能阻尼器耦连的带裙房高层建筑结构地震反应的半主动控制.地震工程与工程振,2000(12):87~95
    [6] Makris N Burton S N, Hill Detal. Analysis and Design of ER Damper for Seismic Protection of Structure. Journal of Engineering Mechanics,1996,122(10):1003~1011
    [7] 周云,吴志远,梁兴文.磁流变阻尼器对高层建筑风振反应的半主动控制.地震工程与工程振动,2001(12):159~162
    [8] Michael D S, Michael C C. Seismic Testing of a Building Structure with a Semi-Active Fluid Damper Control System.Earthquake Engng. Struct.Dyn,1997,26:759~777
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (71) PDF downloads(33) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return