LüLiemin, Cui Demi. DIAGNOSIS OF THICKNESS OF DAMAGED CONCRETE BY ULTRASONIC METHOD[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(2): 81-82,102. doi: 10.13204/j.gyjz200502022
Citation:
LüLiemin, Cui Demi. DIAGNOSIS OF THICKNESS OF DAMAGED CONCRETE BY ULTRASONIC METHOD[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(2): 81-82,102. doi: 10.13204/j.gyjz200502022
LüLiemin, Cui Demi. DIAGNOSIS OF THICKNESS OF DAMAGED CONCRETE BY ULTRASONIC METHOD[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(2): 81-82,102. doi: 10.13204/j.gyjz200502022
Citation:
LüLiemin, Cui Demi. DIAGNOSIS OF THICKNESS OF DAMAGED CONCRETE BY ULTRASONIC METHOD[J]. INDUSTRIAL CONSTRUCTION, 2005, 35(2): 81-82,102. doi: 10.13204/j.gyjz200502022
The thichness of a damaged concrete can be obtained by the following steps:A plane measurement is used to arrange sonic measuring points; the sonic velocity of the concrete within a nondestructive zone is measured first, and then sonic propagation time of different measuring points within a damaged zone and their corresponding plane measured distances are used,which can be transformed by formulas.This method features convenient testing,simple calculation and excellent practicality.