Experimental Study on Seismic Properties of Assembled Integrated Double Shear Walls
-
摘要: 为研究预装修模块化箱体建筑体系中双皮拼装剪力墙的抗震性能,设计了4个双皮拼装剪力墙和1个现浇剪力墙,在一定轴压比下对其进行低周往复加载试验,研究灌浆料强度、插筋直径以及轴压比对其破坏形态、承载力、延性、刚度及耗能的影响。试验结果表明:灌浆料、软索拉环、插筋能将双皮拼装剪力墙连接成整体;双皮拼装剪力墙的破坏形态与现浇墙类似,墙体形成X形交叉裂缝并且低部混凝土压碎;在同一条件下,现浇墙体与双皮拼装剪力墙的极限荷载基本相等;随着轴压比的提高,双皮拼装剪力墙体刚度随之提高。最后,对双皮拼装剪力墙的破坏机理和底部钢筋应变进行了分析。
-
关键词:
- 双皮拼装剪力墙 /
- 抗震性能 /
- 低周往复加载试验 /
- 预装修模块化箱体建筑体系 /
- 软索拉环
Abstract: In order to study the seismic performances of assembled integrated double shear walls in Prefabricated Prefinished Volumetric Construcction (PPVC), four assembled integrated double shear walls and one cast-in-place shear wall were designed to be used for low-cycle reciprocating loading experiments. The effects of grouting material strength, diameters of connecting rebars and axial compression ratios on its failure pattern, bearing capacity, ductility, stiffness,energy consumption were studied. The test results showed that grouting materials, wireropes and connecting rebars could connect the prefabricated shear walls into a whole. The failure form of the assembled integrated double shear walls was similar to that of the cast-in-place wall. X-shaped cross cracks were formed and the lower part of the wall was crushed. In the same condition, the ultimate loads of the assembled integrated double shear walls were basically equal to that of the cast-in-place walls. Increasing axial compression ratios could significantly improve the stiffness of the assembled walls. Finally, the failure mechanism of the assembled walls and the strain of bottom rebars were analyzed. -
[1] 刘状成. 新加坡建筑装配式发展启示[J].墙材革新与建筑节能,2019,24(9):48-52. [2] 王彦博, 吕一凡, 戴子权, 等. 高层建筑模块化建造技术的应用现状与挑战[J]. 工业建筑,2019,49(5):112-116. [3] 黄远,许铭,张锐. 全装配式混凝土结构界面软索连接拼缝抗剪性能试验研究[J]. 湖南大学学报(自然科学版),2014,41(6):22-27. [4] 王滋军,刘伟庆,魏威, 等. 钢筋混凝土水平拼接叠合剪力墙抗震性能试验研究[J]. 建筑结构学报,2012,33(7):147-155. [5] 薛伟辰,李亚,蔡磊,等. 双面叠合混凝土剪力墙平面内和平面外抗震性能研究[J].工程力学,2018,35(5): 47-53. [6] 王平山,崔家春,徐自然,等. 双面叠合剪力墙结构力学性能研究[J]. 建筑结构,2020,50(9):1-8. [7] VAGHEI R, HEJAZI F, TAHERI H,et al. Development of a new connection for precast concrete walls subjected to cyclic loading[J]. Earthquake Engineering and Engineering Vibration,2017,16(1):97-117. [8] HARRILD J, ANDERSEN M, MUTTONI A,et al. Test and lower connections in RC shear walls[J]. Engineering Structures,2018,155(11):115-126. [9] 中华人民共和国住房和城乡建设部.混凝土结构试验方法标准: GB/T 50152—2012[S]. 北京: 中国建筑工业出版社, 2012. [10] 国家市场监督管理局.金属材料拉伸试验第1部分:室温试验方法: GB/T 228.1—2021[S].北京:中国标准出版社, 2021. [11] 中华人民共和国住房和城乡建设部.建筑抗震试验规程: JGJ/T 101—2015[S]. 北京:中国建筑工业出版社, 2015. [12] 中华人民共和国住房和城乡建设部.建筑抗震设计规范:GB 50011—2010[S].北京: 中国建筑工业出版社,2016. [13] 许淑芳, 张弢, 索跃宁, 等. 钢筋混凝土空心剪力墙刚度退化研究[J]. 西安建筑科技大学学报(自然科学版),2007,15(5):605-609.
点击查看大图
计量
- 文章访问数: 68
- HTML全文浏览量: 5
- PDF下载量: 0
- 被引次数: 0