EXPERIMENTAL RESEARCH ON CORRODED H-SHAPED STEEL SHORT COLUMN UNDER ECCENTRIC COMPRESSION
-
摘要: 为研究腐蚀损伤对H型钢压弯构件承载性能的影响,特别是局部屈曲性能,设计了6根不同锈蚀程度的H型钢短柱。首先进行最长达15个月的户外加速腐蚀试验、然后进行板材单调拉伸试验以及短柱的偏心受压试验,最后分析其力学性能参数、破坏模式、极限承载力和变形性能与锈蚀程度的关系。结果表明:随着锈蚀程度的增加,H型钢短柱试件的极限荷载和临界屈曲荷载呈逐渐下降的趋势;锈蚀导致局部屈曲半波长逐渐减小,削弱了试件的塑性变形能力,降低了试件的偏压承载力。Abstract: In order to study the influence of corrosion damage on the bearing capacity of H-shaped steel members under compression, especially the local buckling performance, six short H-shaped steel short columns with different degrees of corrosion were designed. Firstly, the outdoor accelerated corrosion test for up to 15 months was carried out, then the monotonic tensile test of plates and the eccentric compression test of short columns were carried out, finally the relationship between corrosion degree and mechanical property parameters, such as failure mode, ultimate bearing capacity, and deformation property, was analyzed. The results showed that with the increase of corrosion degree, the ultimate load and critical buckling load of H-shaped steel columns decreased gradually; corrosion led to the decrease of the half wavelength of local buckling, which weakened the plastic deformation capacity of the specimen and reduced the bearing capacity of the member under eccentric compression.
-
[1] 徐善华, 张宗星, 苏超,等. 中性盐雾环境锈蚀H型钢柱抗震性能试验研究[J]. 建筑结构学报, 2018, 40(1):49-57. [2] 徐善华, 张宗星, 李柔,等.锈蚀钢框架地震易损性评定方法[J]. 工程力学, 35(12):117-125. [3] XU S H, ZHANG Z X, QIN G C. Study on the Seismic Performance of Corroded H-Shaped Steel Columns[J]. Engineering Structures, 2019, 191:39-61. [4] 杨清梅, 周健鸿. 基于拉伸试验的锈蚀钢板力学性能研究[J]. 低温建筑技术, 2016, 38(5):12-15. [5] WANG Z,LIU J,WU L,et al.Study of the Corrosion Behavior of Weathering Steels in Atmospheric Environments[J]. Corrosion Science, 2013,67(2):1-10. [6] OK D,PU Y,INCECIK A.Computation of Ultimate Strength of Locally Corroded Unstiffened Plates Under Uniaxial Compression[J]. Marine Structures,2007,20(1/2):100-114. [7] 陈梦成, 林博洋, 黄宏. 锈蚀方钢管混凝土短柱轴压承载力研究[J]. 钢结构, 2017,32(5):111-116. [8] 中国国家标准化管理委员会.金属和合金的腐蚀酸性盐雾、"干燥"和"湿润"条件下的循环加速试验:GB/T 24195-2009[S]. 北京:中国标准出版社, 2009. [9] 中国国家标准化管理委员会.热轧H型钢和剖分T型钢:GB/T 11263-2017[S].北京:中国标准出版社,2017. [10] 中国国家标准化管理委员会.金属材料拉伸试验第1部分:室温试验方法:GB/T 228.1-2010[S]. 北京:中国标准出版社, 2010. [11] 中华人民共和国住房和城乡建设部.建筑抗震设计规范:GB 50011-2010[S]. 北京:中国建筑工业出版社, 2016. [12] 王元清,王中兴,殷福新,等. 铝合金受弯构件局部稳定性能试验研究[J]. 建筑结构学报, 2015, 36(8):42-48.
点击查看大图
计量
- 文章访问数: 150
- HTML全文浏览量: 23
- PDF下载量: 2
- 被引次数: 0