EXPERIMENTAL RESEARCH ON MECHANICS OF LONG-SPAN AND HEAVY-LOAD PRESTRESSED CONCRETE DOUBLE-TEES
-
摘要: 为进一步拓宽大跨度预应力双T板的应用范围,设计了一款预应力双T板,其使用活荷载标准值为30 kN/m2,并将其应用于某实验办公楼项目。通过足尺双T板构件的静力荷载试验,获得了构件的变形特性、裂缝发展规律、正截面和斜截面承载力,验证了双T板力学性能可满足大跨重载楼面的使用需求及所采用计算方法的可行性。试验结果表明:预应力双T板具有较好的跨中抗弯和端部抗剪承载力,构件抗裂系数和挠度均满足相关标准和设计要求;双T板肋顶构造设置的桁架钢筋进一步加强了现浇面层与预制部分的整体工作性能,试验过程中未出现现浇面层与预制构件截面开裂情况。提出了合理的构造措施,有效避免了双T板生产及施工过程中肋板顶部及端部企口裂缝的产生,具有实际工程应用价值。Abstract: In order to further expand the application range of long-span prestressed double-tees, a prestressed double-tees was designed, it can withstand a live load of 30 kN/m2, and it was applied to an experimental office building project. Through the static load test of full size double-tees, the deformation characteristics, crack development law, bearing capacity of normal section and inclined section of the double-tees were obtained, and the mechanical properties of double-tees could meet the use requirements of heavy-load floor and the feasibility of calculation method was verified. The results showed that the prestressed double-tees had a suitable bearing capacity at middle span section and shear bearing capacity of dapped end, and the crack resistance coefficient and deflection of the component could meet the requirements of relevant codes and design; the truss reinforcement set on the double-tees rib top further enhanced the cooperative effect performance of the cast-in-place surface layer and the precast part. There was no cracking of the cast-in-place layer and the precast part during the test. The reasonable construction measures were proposed, which could effectively avoid the generation of cracks in rib plate top and dapped end in the production and construction process of double-tees, and having the value of practice.
-
Key words:
- double-tees /
- long-span /
- heavy-load /
- static test /
- bearing capacity
-
庞瑞,梁书亭,朱莜俊.国外预制混凝土双T板楼盖体系的研究[J].工业建筑,2011,41(3):121-126. 陈铁,曹明星,张清亮.双T板在工业厂房中的应用比较[J].工程建设与设计,2008(2):49-51. 何德湛,贾方树.一种房屋建筑的轻型屋盖构件:预应力混凝土双T板[J].预应力技术,2008(5):8-10. 王茂宇,郑毅敏,赵勇.中美预制预应力混凝土双T板构件对比[J].混凝土与水泥制品,2014(8):42-45. FLEISCHMAN R B, SAUSE R, PESSIKI S, et al. Seismic Behavior of Precast Parking Structure Diaphragms[J].PCI Journal,1998(1):38-53. Precast and Prestressed Concrete Institute. PCI Design Handbook[M].7th ed. Chicago,Illinois:PCI,2010. 中华人民共和国住房和城乡建设部. 预制预应力混凝土装配整体式框架结构技术规程:JGJ 224-2010[S].北京:中国建筑工业出版社,2010. 中国有色工程有限公司. 混凝土结构构造手册[M].5版.北京:中国建筑工业出版社,2016. 张辉,赵勇,程春森. 预制混凝土双T板企口端部受力性能试验研究[J].建筑结构学报,2018,39(增刊2):28-35. ACI Committee 318. Building Code Requirements for Structural Concrete and Commentary:ACI 318/318R-11[S]. Farmington Hills,MI:American Concrete Institute,2011. 中华人民共和国住房和城乡建设部.混凝土结构设计规范:GB 50010-2010[S].北京:中国建筑工业出版社,2015. 中华人民共和国住房和城乡建设部.混凝土结构工程施工质量验收规范:GB 50204-2015[S]. 北京:中国建筑工业出版社,2015. 中华人民共和国住房和城乡建设部.建筑地基基础设计规范:GB 50007-2011[S].北京:中国建筑工业出版社,2011. 期刊类型引用(7)
1. 许开成,黄凌娟,李鹏清,张立卿,邱日旭,陈梦成. 基于缩尺模型的高铁桥梁预应力损失试验研究. 华东交通大学学报. 2024(02): 48-55 . 百度学术
2. 郭呼胜,闫斌斌,姚建廷,王志刚. 双T型截面屋面板静载试验与数值模拟研究. 工程质量. 2024(12): 48-51 . 百度学术
3. 范宗帅,冯西龙,赵伟,刘航. 预应力双T板肋梁端部裂缝成因及预防措施. 建筑施工. 2023(04): 650-653 . 百度学术
4. 王晓锋,那振雅,赵广军,韩伟涛. 预应力混凝土双T板结构性能研究与工程应用进展. 工业建筑. 2023(03): 12-20 . 本站查看
5. 华慧娟,李富民. 装配施工荷载下约束垫层混凝土拌合物的受压徐变性能. 徐州工程学院学报(自然科学版). 2023(02): 37-43 . 百度学术
6. 王洪欣,孙占琦,钟志强,芦静夫,黄朝俊. 预制预应力混凝土楼板设计关键技术与应用. 混凝土与水泥制品. 2022(11): 63-67 . 百度学术
7. 刘之春,刘军宇. 屋面预应力混凝土双T板端部腹板裂缝原因分析与加固处理. 计算机辅助工程. 2021(04): 1-5 . 百度学术
其他类型引用(1)
-

计量
- 文章访问数: 112
- HTML全文浏览量: 11
- PDF下载量: 4
- 被引次数: 8