摘要: 结合装配式钢结构建筑工程实例,研究了装配式外围护墙板的性能。对比了6种复合墙板的保温性能,并选定ALC+岩棉复合箱型"三明治"墙板进行工程应用。对ALC复合墙板进行了加载试验,试验结果满足设计的力学性能要求,在计算式难以确定的情况下,推荐采用基于试验确定墙板抗力设计值。对该墙板进行了工程应用,安装效果良好。Abstract: Combined with the example of prefabricated steel structure construction, the prefabricated enclosure wallboard was studied. The thermal insulation performance of six kinds of composite wallboard was compared, and a box-type ALC+rock wool composite "sandwich" wallboard was selected for engineering application. The loading test of ALC composite wallboard was carried out, and the test results could meet the design requirements of mechanical properties. When the calculation formula was difficult to determine, it was recommended to determine the design value of wallboard resistance based on the test. The wallboard had been applied in engineering with good results.
-
贺灵童,陈艳.建筑工业化的现在与未来[J].工程质量,2013,31(2):1-8. 李湘洲.国外住宅建筑工业化的发展与现状(一):日本的住宅工业化[J].中国住宅设施,2005(1):56-58. 严薇,曹永红,李国荣.装配式结构体系的发展与建筑工业化[J].重庆建筑大学学报,2004(5):131-136. 孔祥秋,纵兆峰.钢结构建筑的围护结构研究[J].山西建筑,2008,34(36):152-154. 刘炜,杨秋鸣.钢结构住宅建筑外墙围护结构做法及材料研究与分析[J].建材技术与应用,2017(3):17-20. 中华人民共和国住房和城乡建设部. 民用建筑热工设计规范:GB 50176-2016[S].北京:中国建筑工业出版社, 2017. 张国伟,陈博珊,肖伟,等.蒸压加气混凝土外挂墙板受弯性能研究[J].建筑结构,2016,46(13):97-102. 寅志强. 装配式混凝土复合外墙板力学性能研究[D].北京:中冶建筑研究总院有限公司,2013. 田钧元. 装配式轻质混凝土围护墙板受力性能研究[D].中冶建筑研究总院有限公司,2018. DAVIES J M. Lightweight Sandwich Construction[M]. UK:Blackwell Science Ltd, 2008. 法国标准化协会. 欧洲法规.结构设计基础:NF P06-100-1/NA-2011[S].圣丹尼:法国标准化协会,2003. 中华人民共和国住房和城乡建设部. 工程结构可靠性设计统一标准:GB 50153-2008[S]. 北京:中国建筑工业出版社, 2008. International Organization for Standardization. General Principles on Reliability for Structures:ISO 2394-2015[S].Switzerlowd:IHS. 尚仁杰,杨潇,寅志强,等.基于试验的轻质围护墙板承载力设计值取值方法[J].工业建筑,2019,49(12):166-170.
点击查看大图
计量
- 文章访问数: 56
- HTML全文浏览量: 8
- PDF下载量: 4
- 被引次数: 0