槽钢加劲钢板剪力墙受力性能研究
doi: 10.13204/j.gyjz201410030
MECHANICAL BEHAVIOR STUDY OF STEEL PLATE SHEAR WALLS WITH CHANNEL STIFFENERS
-
摘要: 竖向槽钢加劲钢板剪力墙由内嵌钢板、边缘构件和墙板两侧对称布置的竖向槽钢加劲肋组成。槽钢加劲肋具有较高的抗弯、抗扭刚度,可为墙板提供有效的面外约束和轴向支撑作用。利用有限元分析软件ABAQUS对槽钢加劲钢板墙进行屈曲分析和静力弹塑性分析,研究槽钢距边缘构件距离、钢板宽厚比、高厚比、肋板刚度比和柱刚度对钢板墙及边缘构件力学性能的影响。结果表明,槽钢加劲肋至边缘构件的距离主要影响钢板墙的平面外变形,对钢板墙屈曲应力和承载力的影响较小。槽钢加劲肋可以有效提高墙板的屈曲应力。随着宽厚比和高宽比的减小,结构的承载力和刚度均显著提高。增大肋板刚度比可提高钢板墙的初始刚度和屈曲应力,肋板刚度比应大于20。为避免边框柱变形过大或过早破坏,边框柱应具有足够的刚度,增大柱刚度可以提高钢板墙的初始刚度,减缓墙板刚度的退化。Abstract: Steel plate shear wall ( SPSW) with channel stiffener consists of infill steel plates,boundary elements and symmetric channel stiffeners. The channel stiffeners with a greater flexural rigidity can provide out-plane restraint effectively. It was carried out buckling analysis and elastoplastic analysis of the mechanical behavior of SPSWs with channel stiffeners by ABAQUS. The analytical results show that the distance between channel stiffeners and boundary elements has influence on the out-plane deformation of SPSW,but no influence on critical buckling stress and lateral load capacity of the SPSW. The channel stiffeners can increase the critical buckling stress effectively. With the decrease of width-to-thickness ratio and aspect ratio,the load capacity and stiffness of SPSW increase greatly. In order to increase the stiffness of SPSW,the stiffener-to-plate stiffness ratio should be greater than 20. In order to prevent the greater deformation and premature failure of the columns,the columns must have enough stiffness. The stiffness of SPSW increases and degrades slowly with the increase of the stiffness of column.