EXPERIMENTAL STUDY ON BEARING CAPACITY OF LIGHT-WEIGHT ENERGY-SAVING COMPOSITE FLOOR SLABS
-
摘要: 提出一种复合节能轻质楼板,它具有围护、分隔、保温及承重等多种功能合一的特点。通过对6个全比例尺寸的复合节能轻质楼板试件在竖向荷载作用下的受力性能试验研究,研究集中和均布荷载作用下复合节能轻质楼板的受力特点及破坏模式,分析复合节能轻质楼板受弯承载力的影响因素。为建立计算公式提出了建议,试验数据可为今后制定相关规范提供依据。Abstract: It was presented a new light-weight energy-saving composite floor slab, which composed of light-gauge shaped steel, thermal insulation core material and thin panel.The light-weight energy-saving composite floor slab integrates the functions of enclosure, separation, heat-insulation and load-bearing.The paper presented the test of six floor slab specimens in full-scale under concentrated load.According to the damage process and test data, it was studied damage pattern and forced featurse of the floor slab.It was put forward that suggestions on creating calculation formula of bending capacity, and the test data provided a basis for working out relevant codes in the future.
-
杨勇,李慧静,薛建阳.钢板-混凝土空心组合板受力性能与设计方法研究[J].工业建筑,2012,42(12):121-125. [2] 季小莲,刘阳军,吴耀华.开孔板式抗剪件受力性能试验研究[J].工业建筑,2012,42(10):138-141. [3] 贾连光,李庆文,张曰果.钢-混凝土蜂窝组合梁抗剪性能分析[J].工业建筑,2012,42(9):155-161. [4] 黄炜,张振中,赵冬等.几种新型工业化住宅结构体系综述[J].工业建筑,2012,42(8):126-132. [5] 辛连春,沈晓明,舒赣平,等.不锈钢受弯构件的试验研究[J].工业建筑,2012,42(5):38-45. [6] 陈军,郝际平.腹板双角钢连接框架-钢板剪力墙体结构滞回性能有限元分析[J].钢结构,2012,27(10):6-11. [7] 焦生留,惠颖.冷弯薄壁槽钢轴压柱的卷边研究[J].钢结构,2011,26(11):13-16. [8] GB/T 2282002金属材料室温拉伸试验方法[S]. [9] GB/T 176571999人造板及饰面人造板理化性能试验方法[S]. [10] GB 500182002冷弯薄壁壁型钢技术规范[S]
点击查看大图
计量
- 文章访问数: 109
- HTML全文浏览量: 7
- PDF下载量: 98
- 被引次数: 0