EXPERIMENTAL STUDY ON BRICK WALLS STRENGTHENED WITH SIDED LATTICED STEEL PLATE
-
摘要: 通过对高宽比为0.7和1.75的4片墙体进行拟静力试验,研究单面格构式钢板加固砖砌体墙后,墙体的破坏特征以及承载力、变形性能等抗震性能的改善情况。其中2片为对比墙,另2片为单面格构式钢板加固墙体。试验结果表明:单面格构式钢板加固砖墙后,高宽比为0.7的墙体承载力提高约50%,高宽比为1.75的墙体承载力基本没有提高,加固后墙体的变形性能得到了较大的提高。Abstract: Pseudo-static test of four walls with aspect ratio of 0.7 and 1.75 was carried out to study the improvement of seismic performance of sided latticed steel plate reinforced brick masonry wall,the wall failure characteristics and bearing capacity and deformation properties.Of which 2 walls were the reference ones,and the other two were sided lattice steel plate reinforced walls.The experimental results showed that the bearing capacity of side latticed steel plate reinforced brick wall of 0.7 aspect ratio increased by about 50%,basically no increase in wall bearing capacity of 1.75 aspect ratio,the deformation properties of reinforced wall were greatly improved.
-
Key words:
- brick wall /
- sided latticed steel plate /
- seismic performance /
- pseudo-static test
-
张京街,林文修,张国彬.钢结构在砖混房屋抽墙加固中的应用[J].工业建筑,2006,36(增刊):1069-1070. [2] 熊鸳,胡松.一种用钢结构加固砖混结构的新方法[J].成都大学学报:自然科学版,2006,25(2):88-89,93. [3] 郭华忠,敬登虎.钢板-砖砌体组合结构在砖混房屋大空间改造中的应用[J].工程抗震与加固改造,2009,31(5):131-133. [4] 童敏,彭少民.钢-砌体组合结构在砖混建筑改造中的应用[J].武汉理工大学学报,2007,29(增刊Ⅱ):152-156. [5] 敬登虎,曹双寅,郭华忠.钢板-砖砌体组合结构托换改造技术及应用[J].土木工程学报,2009,42(5):55-60. [6] 王成祥.混合结构承重砌体房屋部分改造为大空间的作法[J].建筑技术,2005,36(9):706-707. [7] 黄泽德.建筑加固技术疑难工程案例[M].北京:中国建筑工业出版社,2007. [8] 欧阳煜,刘能科.外包钢加固轴心受压砖柱的受力性能分析[J].建筑结构,2006,36(11):27-29. [9] 卓尚木,林茂合,陈丽梅.砖柱外包钢加固的强度和变形[J].建筑结构,1994,24(5):12-17.