SEISMIC DESIGN OF BUILDING A OF MINDA PLAZA
-
摘要: 民大广场A楼为带转换层的型钢框架-剪力墙结构体系,因建筑功能的需要,结构外框架不设框架梁,外框架柱为纺锤状斜柱,转换层采用新型组合结构转换梁。所采用的结构通过基于性能的抗震分析、拟静力试验和振动台试验等验证是可行的,其破坏机制遵循强柱、弱梁、更强转换梁、最强节点区的原则。双型钢混凝土转换梁具有较强承载能力和较好耗能性能。Abstract: The building A of Minda Plaza was adopted the SRC frame and shear wall structural system.Due to the functional need,the beams were deleted from the spindle-shape outmost frames,where the columns were arranged in an inclined orientation with the principal floor axes.The transfer story was of particular challenge,thus a new type of composite beam with encased built-up double steel sections was designed.The satisfactory performance of the new structural system was validated through quasi-static loading tests and shake-table test.The structure was exhibited to follow the failure mechanism of strong columns,weak beams,stronger transfer beams,and the strongest connection.The steel reinforced concrete transfer beams with double-steel sections had satisfactory bearing capacity and energy dissipation capacity,suitable to meet the requirements of functional limitation.
-
[2] YB 90822006钢骨混凝土结构设计规程[S]. JGJ 1382001型钢混凝土组合结构技术规程[S]. [3] 叶列平,方鄂华.钢骨混凝土构件的受力性能研究综述[J].土木工程学报,2000,33(5):1-11. [4] 田玉基,梁书亭,蒋永生,等.钢骨混凝土梁式托柱转换层结构的研究[J].工业建筑,2000,30(2):54-57. [5] 李俞渝,徐其功,徐天平,等.劲性混凝土转换箱梁包劲性混凝土柱的连接节点:中国,ZL200910042004.5[P].2009-08-20.
点击查看大图
计量
- 文章访问数: 102
- HTML全文浏览量: 6
- PDF下载量: 121
- 被引次数: 0