EXPERIMENTAL STUDY ON THE BEHAVIOR OF STEEL TUBE SHORT COLUMS FILLED WITH RECYCLED CONCRETE UNDER AXIAL COMPRESSION
-
摘要: 通过对6根钢管再生混凝土短柱及3根普通钢管混凝土短柱进行轴压试验,研究不同长径比和再生骨料取代率对钢管再生混凝土短柱轴压力学性能的影响。研究结果表明:钢管再生混凝土短柱的变形破坏形式与普通钢管混凝土短柱相似;随再生骨料取代率及长径比的增加,钢管再生混凝土短柱的极限承载力下降。基于试验验证普通钢管混凝土短柱极限承载力计算方法对钢管再生混凝土短柱的适用性,计算值与试验值吻合较好。
-
关键词:
- 薄壁钢管再生混凝土短柱 /
- 钢管混凝土短柱 /
- 轴压试验 /
- 抗压承载力
Abstract: Based on axially compressive tests of 6 recycled concrete filled steel tube short columns and 3 common concrete filled steel tube short columns,the influence of replacement percentages of recycled aggregate and longitude to diameter ratio on compressive capacity was studied in this paper.The test results demonstrated that the recycled concrete-filled steel tube short column and common concrete-filled steel tube short column had similar deformation and failure mode.The greater the longitude to diameter ratio and replacement percentages of the recycled aggregate,the lower the compressive capacity of specimens;the formula for the calculation of the ultimate compressive capacity of common concrete filled steel tube short column was also applicable to recycled concrete filled steel tube short column. -
[2] Evangelista L,Brito I.Mechanical Behavior of Concrete Made withFine Recycled Concrete Aggregates[J].CementConcreteComposites,2007,29(5):397-401. 朱红兵,王顺林,熊汉林,等.混凝土废弃物的再生利用[J].公路交通技术,2005(1):52-53. [3] Eguchi K,Teranishi K,Nakagome A,et al.Application ofRecycled Coarse Aggregate by Mixture to Concrete Construction[J].Construction and Building Materials,2007,21(7):1542-1551. [4] 李佳彬,肖建庄,黄健.再生粗骨料取代率对混凝土抗压强度的影响[J].建筑材料学报,2006,9(3):297-301. [5] 徐恩祥.再生混凝土基本力学性能试验研究[D].南京:南京工业大学,2010. [6] 肖建庄,李佳彬,兰阳.再生混凝土技术研究最新进展与评述[J].混凝土,2003(10):17-20. [7] 吴凤英.钢管再生混凝土轴压力学性能研究[D].福州:福州大学,2007. [8] 邱慈长,王清远,石宵爽,等.薄壁钢管再生混凝土轴压实验研究[J].实验力学,2011,26(1):8-14. [9] 肖建庄,杨洁,黄一杰,等.钢管约束再生混凝土轴压试验研究[J].建筑结构学报,2011,32(6):92-98. [10] 李斌,郝润霞.钢管混凝土柱的承载力分析[J].包头钢铁学院学报,2005,24(1):5-8.
点击查看大图
计量
- 文章访问数: 54
- HTML全文浏览量: 5
- PDF下载量: 86
- 被引次数: 0