摘要: 通过1片未加固带壁柱砖墙和5片玻璃纤维复合材料(GFRP)加固带壁柱砖墙,其中3片采用对拉锚固措施,在低周往复荷载作用下进行抗震性能试验,阐述各试件的破坏特征;研究对拉锚固措施以及加固量对GFRP加固前后墙体的刚度及退化特性、变形性能、耗能性能等影响。研究结果表明:采用对拉锚固减小后期墙体刚度的衰减;对拉锚固对墙体变形能力有一定程度的影响,且比加固方式影响大;在极限荷载状态下,采用锚固措施对试件耗能性能的影响不明显,但在极限位移状态下,锚固措施的采用明显地改善墙体的耗能性能。
-
关键词:
- 玻璃纤维复合材料(GFRP) /
- 加固 /
- 带壁柱砖墙 /
- “对拉”锚 /
- 抗震性能
Abstract: It was carried out an experimental research on seismic performance of brick masonry walls with pilasterreinforced by glass GFRP whenthrough-wall anchors were used. By carrying out the experiment of six pieces ofbrick masonry walls with pilaster strengthened by GFRP and three pieces of masonry wall with through-wallanchor under low reversed cyclic loading, the failure characteristic of every wall was explained ; Seismicperformances such as resilience, rigidity and its degeneration, deformation, energy consumption ifthrough-wallanchors were taken or not. The test results showed that using through-wall anchors could decrease rigiditydegeneration of the wall; through-wall anchors had some influence on deformation of the wall, and was betterthan strengthening modes; Usingthrough-wall anchors had little influence on energy consumption of the wallsunder the ultimate load, but was another thing under the ultimate displacement. -
王全凤,黄奕辉.纤维增强复合材料与砖界面剥离模型[J].工程力学,2009,26(10):50-58. [2] 王欣.纤维复合材料加固砌体墙片的抗震试验研究[D].上海:同济大学,2003. [3] 张祥顺,谷倩,彭少民.CFRP对砖墙抗震加固对比试验研究与计算分析[J].世界地震工程,2003,19(1):77-82. [4] Albert L Michael,Elwi E Alaa,Cheng J J Roger. Strengthening of Unreinforced Masonry Walls Using FRPs [J]. Journal of Composites for Construction,2001,5 (2): 76-84. [5] 林磊,叶列平.GFRP布加固砌体墙的试验研究[C]∥第二届全国土木工程用纤维增强塑料(FRP)应用技术学术交流会会议论文集.昆明:2002:215-223. [6] 陆新征.FRP-混凝土界面行为研究[D].北京:清华大学,2004. [7] 赵彤,刘明国.碳纤维布用于改善斜向受力高强混凝土柱抗震性能的研究[J].土木工程学报,2002(6):13-19. [8] 赵彤,张景明.碳纤维布改善钢筋混凝土短柱延性的试验研究[J].世界地震工程,2002(3):83-86. [9] 张伟平,欧阳煜,顾祥林,等.FRP板加固砌体结构的抗震性能试验研究[C]∥第六届全国建筑物鉴定与加固改造学术会议论文集.长沙:湖南大学出版社,2002:450-456. [10] JGJ10196建筑抗震试验方法规程[S].
点击查看大图
计量
- 文章访问数: 118
- HTML全文浏览量: 8
- PDF下载量: 74
- 被引次数: 0