EXPERIMENTAL STUDY ON THE BEHAVIOR OF REDISTRIBUTION OF INTERNAL FORCE OF REINFORCED CONCRETE TUBULAR CORED SLAB
-
摘要: 圆管式空心板是一种使用GBF系列高强薄壁管作为永久性内模的空心板。通过试验对两种不同布管方式的圆管式空心板进行了塑性内力重分布性能研究。其中一种试验板为将GBF高强薄壁管平行跨径方向布置的顺管向板,另一种为将GBF高强薄壁管垂直跨径方向布置的横管向板。研究表明:圆管式空心板具有良好的内力重分布性能;顺管向板至少在30.7%的弯矩调幅幅度下均满足承载能力要求和正常使用要求;横管向板至少在27%的调幅幅度下满足承载能力要求和正常使用要求。并且,圆管式空心板受弯时的截面弯矩-曲率关系近似地符合二折线本构模型。Abstract: Tubular hollow slab is the hollow slab whose internal mold is permanent internal mold of GBF serial highstrength thin-wall pipe. Experimental study on the behavior of plastic internal force redistribution of two kinds of tubular hollow slabs which have different arrangement manner of the high-strength thin-wall pipes was conducted.One of the experimental slabs was called parallel slab inside which the GBF high-strength thin-walled tubes wereplaced to be parallel with the span direction, the other was called vertical slab inside which the GBF thin-walledtubes were placed to be vertical with the span direction. It was indicated from the study that the tubular hollowcontinuous slab had good performance of plastic internal force redistribution. The parallel slab could meetrequirements of the bearing capacity and the regular service when the value of moment modulating is 30. 7 % at least.And the vertical slab could meet requirements of the bearing capacity and the regular service when the value ofmoment modulating is 27 % at least. And, the moment-curvature relationship of section approximately conforms tothe constitutive model of two straight lines.
-
[2] 马克俭,张汉平,张华刚,等. 现浇混凝土类椭圆单向空心板柱结构的研究与应用[J]. 工业建筑,2001,31 (增刊 ): 91-97. JC / T 952 2005 玻璃纤维增强水泥永久性管状芯模[S]. [3] 全学友,孙会郎,王 巍. 现浇圆形管空心楼盖中单向模型板受力性能的试验研究[J]. 建筑结构学报,2005,26 (5 ): 53-59. [4] Yang Weijun,Zhang Zhenhao,Liu Chenwei,et al. Experimental Study on Simply Supported Slab of Reinforced Concrete Stiffening Ribbed Hollow Pipe Girderless Floor[C]// Proceedings of the Ninth International Symposium on Structural Engineering for Young Experts. 2006. [5] 杨伟军,张振浩,刘 赪 炜. 加 劲 肋 空 心 管 现 浇 钢 筋 混 凝 土 无 梁楼盖受力性能试验研究[J]. 工业建筑,201 0,40(9 ): 41-47. [6] Yang Weijun,Zhang Zhenhao,Liu Chenwei. Experimental Study on Mechanical Property of Stiffening-Ribbed-Hollow-Pipe Cast-in Place Reinforced Concrete Girderless Floor[J]. Journal of Civil Engineering and Architecture,2009,3 (3 ): 59-69. [7] CECS 51∶ 93 钢筋混凝土连续梁和框架 考虑内力重分布设计规程[S]. [8] GB 501 52 92 混凝土结构试验方法标准[S]. [9] 李峰. 现浇钢筋混凝土 空心板中管参与工 作的性能 研 究[D].天津: 天津大学,2004. [1 0] 马永欣,郑山锁. 结构试验[M]. 北京: 科 学 出 版 社,2001: 65 -66. [11] 杨伟军,张振浩. GBF 钢筋混凝土空 心板正常使用阶段的裂缝分析[J].中外公路,2009,29( 2) : 141 -144.
点击查看大图
计量
- 文章访问数: 106
- HTML全文浏览量: 7
- PDF下载量: 51
- 被引次数: 0