EXPERIMENTAL RESEARCH ON THE BEARING CAPACITY OF REINFORCED CONCRETE POLE STRENGTHENED BY CARBON FIBER REINFORCED POLYMER
-
摘要: 为了揭示采用碳纤维布(CFRP)加固钢筋混凝土电杆后的破坏机理和承载性能,完成4根混凝土电杆的试验研究,其中3根为碳纤维布加固的电杆和1根作对比的未加固电杆。通过试验观察各试件的受力全过程和破坏形态,获取荷载-位移全过程曲线和极限承载力等重要参数。研究结果表明:碳纤维布加固后,混凝土电杆的破坏过程没有明显预兆,破坏过程迅速,破坏形态表现为碳纤维被拉断;碳纤维布加固后,钢筋混凝土电杆的极限承载力有显著提高,提高的程度与碳纤维布粘贴层数有关,随着碳纤维布粘贴层数的增加,极限承载能力也跟着提高,但提高的程度与碳纤维布粘贴层数不呈比例。
-
关键词:
- 碳纤维布(CFRP) /
- 钢筋混凝土电杆 /
- 加固 /
- 承载能力
Abstract: In order to reveal the failure mechanism and bearing capacity of extended service reinforced concrete pole strengthened with carbon fiber reinforced polymer (CFRP),4 reinforced concrete poles were designed for bending test,including three reinforced concrete poles strengthened by CFRP and one common reinforced concrete pole. According to the test,the whole failure process,failure pattern,the complete loading-displacement curve and the ultimate bearing capacity were obtained. Experimental results showed that the failure progress of CFRP strengthening reinforced concrete pole was very rapid and no premonition,CFRP fracture was the final failure pattern of specimens. The concrete pole bearing capacity was improved apparently by CFRP strengthening technology. With the layer of CFRP increasing,the bearing capacity was improved,but the improvement was not linear. -
[2] 梁前东.碳纤维在混凝土电杆加固中的应用[J].广东建材,2011(5):58-59. 刘思远,夏开全,陈宗平.在役钢筋混凝土电杆抗弯承载能力研究[J].混凝土,2011(6):60-63. [3] 曹双寅,蔺新艳,敬登虎,等.外贴碳纤维布加固钢筋混凝土梁裂缝性能试验研究[J].建筑结构学报,2010,31(1):33-40. [4] 董江峰,王清远,邱慈长,等.外贴碳纤维布加固混凝土梁断裂特性的试验研究[J].土木工程学报,2010,43(增刊): 76-82. [5] 周戟,赵少伟,孙吉书.碳纤维布加固已损伤混凝土梁抗弯刚度研究[J].河北工业大学学报,2010,39(3): 116-118. [6] 张广泰,刘清,王克新.碳纤维布加固钢筋混凝土梁的抗弯试验和数值分析[J].工业建筑,2009,39(8): 80-83. [7] 王志滨,陶忠.FRP-混凝土-钢管组合受弯构件力学性能试验研究[J].工业建筑,2009,39(4): 5-8. [8] 卜良桃,宋力,施楚贤.碳纤维板加固钢筋混凝土梁的抗弯试验和理论研究[J].建筑结构学报,2007,28 (1): 72-79. [9] 孙石.FRP 筋受弯构件正截面承载力极限状态的设计[J].工业建筑,2006,36(增刊): 362-364. [10] GB 500102010 混凝土结构设计规范[S].
点击查看大图
计量
- 文章访问数: 125
- HTML全文浏览量: 6
- PDF下载量: 71
- 被引次数: 0