EXPERIMENTAL STUDIES ON SEISMIC BEHAVIORS OF RC COLUMNS WITH HRB500 LONGITUDINAL REINFORCEMENTS CONSIDERING CONFINEMENT OF STIRRUPS
-
摘要: 通过对各国规范中柱子箍筋加密区的构造对比,发现中国规范与国外规范在配箍特征值的取值上有较大差别。此外,在钢筋混凝土柱中采用更高强度的HRB500钢筋后,按照GB 500102010《混凝土结构设计规范》设计的柱子其抗震性能是否能达到要求也需进行验证。通过对9根配置HRB500纵筋柱进行低周反复荷载试验,分析配箍率、配箍特征值、箍筋强度以及配箍形式等因素对柱的破坏状态、P-滞回曲线、延性、刚度退化以及耗能能力的影响;对比分析条件基本相同情况下配置HRB500纵筋柱与配置HRB335纵筋柱受力性能的差异。研究结果表明,当柱端箍筋加密区的构造满足要求时,配置HRB500纵筋柱能够满足抗震结构对柱的变形能力以及位移延性的要求。Abstract: In the specifications on detailing of stirrups and minimum hoop characteristic factors in column hoop densified regions,there exists large difference between Chinese Codes and related codes of other countries.So it is necessary to check the seismic behaviors of columns with different transverse reinforcement schemes in different codes.Moreover,it is needed to verify the seismic behaviors of columns designed to Chinese Codes using HRB500 rebars with a higher strength as longitudinal reinforcements.Reverse cyclic loading tests of 9 RC column specimens reinforced with HRB500 rebars were conducted.The test parameters included the transverse reinforcement ratio,hoop characteristic value,stirrup strength and arrangement of stirrups.The effects of these parameters on the failure mechanism,load-deflection hysteretic-curve,ductility,stiffness degradation and energy-dissipating capacity were analyzed.Different behaviors between the columns with HRB500 rebars and those with HRB335 rebars were discussed,with other parameters remaining the same.The results showed that when the details of stirrups in hoop densified regions confirming to the design codes,the columns reinforced with HRB500 rebars could meet the seismic requirements of deformability and ductility.
-
阎石,肖潇,张日果. 高强钢筋约束混凝土矩形柱的抗震性能试验研究[J].沈阳建筑大学学报(自然科学版),2006,(01):7-10. 张国军,吕西林,刘建新. 高强约束混凝土柱基于位移的抗震设计[J].同济大学学报(自然科学版),2007,(02):143-148. 吕西林,张国军,陈绍林. 高轴压比高强混凝土足尺框架柱抗震性能研究[J].建筑结构学报,2009,(03):20-26. 李瑞锋,姚会欣. 高强混凝土框架柱抗震性能试验研究[J].四川建筑科学研究,2009,(04):180-182. 李瑞锋,姚会欣. 配箍特征值对高强混凝土框架滞回特征的研究[J].四川建筑科学研究,2008,(04):60-63. 李瑞锋,姚会欣. 箍筋形式对高强混凝土框架柱滞回特性的研究[J].四川建筑科学研究,2008,(03):24-26. 管品武,郭海峰,雷士发. HRB500钢筋混凝土框架柱塑性铰区破坏形态的试验研究[J].四川建筑科学研究,2009,(05):134-136. Muguruma H,Watanabe F. Ductility Improvement of High- Strength Concrete Columns with Lateral Confinement[J].ACI Journal,1990,(SP-121):47-60. Budek A M,Priestley M J N,Chin Ok Lee. Seismic Design of Columns with High-Strength Wire and Strand as Spiral Reinforcement[J].ACI Journal,2002,(05):605-615. ACI 318-08.Building Code Requirements for Structural Concrete and Commentry[S]. CSA Standard A 23.3-04.Design of Concrete Structures[M]. NZS3101.New Zealand Standard Code of Practice for the Design of Concrete Structures[S]. Eurocode 8.Design Provision for Earthquake Resistance of Structure[S]. GB50010--2002混凝土结构设计规范[S]. 李扬. 抗震钢筋混凝土柱非线性变形分解试验及模拟分析[D].重庆:重庆大学,2010. 赵亮. 配置不同强度等级钢筋的混凝土结构非线性动力反应分析[D].重庆:重庆大学,2009.
点击查看大图
计量
- 文章访问数: 101
- HTML全文浏览量: 7
- PDF下载量: 98
- 被引次数: 0