JOINTLESS CONSTRUCTION TECHNOLOGY ANALYSIS OF FOUNDATION CONCRETE FOR HENAN TV TOWER
-
摘要: 河南省广播电视发射塔基础结构形式为桩筏复合基础,基础底板未设置后浇带和膨胀加强带,属超长结构无缝施工。通过对河南广播电视发射塔基础的大体积混凝土超长无缝施工技术的介绍及各测试位置的相邻测点温差的监测表明,混凝土各测点温差均未超过监测报警温差25℃,没有产生较大的温度梯度。整个底板施工完成后未产生裂缝,混凝土裂缝得到了有效控制。该技术可控制大体积超长混凝土结构裂缝的产生。Abstract: The foundation type of Henan broadcast and TV tower is a pile raft foundation.The jointless construction technology of mass concrete is analyzed for its foundation slab has no post poured belt and concrete expansion and strengthened belt.It was introduced the jointless construction technology of the TV tower mass concrete.The results showed that temperature difference of two adjacent measuring points at the same position is less than 25 ℃.The technology controlled concrete crack effectively and provided construction experience for construction of similar projects.
-
Key words:
- mass concrete /
- foundation construction /
- construction technology
-
王寿华,王家隽,朱维益,等.建筑施工手册(缩印本)[M].4版.北京;中国建筑工业出版社,2003. [2] 李尊忠,何宁,崔冬.某电厂储煤筒仓基础大体积混凝土施工技术[J].工业建筑,1999,29(12);68-71. [3] JGJ 552000普通混凝土配合比设计规程[S]. [4] GB 501192003混凝土外加剂应用技术规范[S]. [5] GBJ 14690粉煤灰混凝土应用技术规范[S]. [6] 林兴军,董义光.核岛厂房底板大体积混凝土裂缝控制的几项技术[J].建筑技术,2002,33(4);283-289. [7] 中国建筑第八工程局.混凝土结构工程施工技术标准(ZJQ 08SGJB 2042005),建筑工程施工技术标准[M].北京;中国建筑工业出版社,2005. [8] 韩国平,刘志宏,熊明安,等.大体积承台混凝土施工技术探讨[J].工业建筑,2008,38(增刊);909-910. [9] 闫小军.浅谈混凝土裂缝的原因及灌浆处理[J].建筑科学,2010,31;67-67. [10] 钱华懋,蔡晓萌.大体积混凝土温度裂缝的成因及控制[J].工业建筑,2008,38(增刊);919-921.