STUDY ON THE INSULATION PERFORMANCE OF METAL FACE SANDWICH PANELS UNDER FIRE
-
摘要: 通过对夹芯板受火时隔热性能进行有限元分析研究,得到不同厚度岩棉夹芯板和聚苯乙烯泡沫EPS及聚氨酯TPU夹芯板的耐火极限,并与试验值进行对比;最后,针对通常不符合防火下隔热要求的夹芯板提出改进措施,以满足规范要求。Abstract: This paper studied the sandwich insulation performance under the fire through the finite element method and gained the fire ratines of rock wool and EPS core sandwich panels which agreed with the test results well.Finally,a new arrangement was proposed to improve the fire rating to satisfy the requirements of the current code.
-
Key words:
- metal surface sandwich panel /
- fire /
- thermal insulation
-
徐峰,张雪芹,华七三.建筑保温隔热材料与应用[M].北京:中国建筑工业出版社,2007:1-5. [2] 吴蓉,熊耀清.关于我国新形势下建筑节能的思考[J].国外建材科技,2006,27(6):88-92. [3] 郑瑾,张其林.建筑用夹芯板研究综述[C]∥第六届全国现代结构工程学术研讨会论文集.2006:1608. [4] 龚学军,白洁,彭连臣.彩钢板结构临建房屋的火灾危险性及防范对策[J].消防技术,2007(4):14-15. [5] 王建平.夹芯板在建筑中的应用研究[J].国外建材科技,2007,28(4):75-76. [6] 王海忠,何保康,孙杰.建筑夹芯板简介[C]∥中国钢结构协会1999学术年会论文集.1999:41-45. [7] Davies J M.Sandwich Panels[J].Thin-Walled Structures,1993,16:179-198. [8] Davies J M.Design Criteria for Structural Sandwich Panels[J].The Structural Engineer,1987,65A(12):435-441. [9] Allen H G.Analysis and Design of Structural Sandwich Panels[M].New York:Pergamon Press,1969. [10] Kuenzi E W.Structural Sandwich Design Criterial[R].NationalAcademy of Sciences-National Research Council,1960:9-18. [11] Hartsock J A.Design of Foam Filled Structures[M].TechnomicPublishing Co.,1969. [12] Allen H G.Sandwich Construction[R].Universit of Southampton,Department of Civil Engineering,1972. [13] Allen H G.Sandwich Panels with Thick or Flexurally Stiff Faces[C]∥Conf.on Sheet Steel in Building.London:Metals Society,1973:10-18. [14] Davies J M.Lightweight Sandwich Construction[M].BlackwellScience Ltd,2001:195-215. [15] Looyeh M R E.Thermochemical Responses of Sandwich Panels toFire[J].Finite Elements in Analysis and Design,2001,37:913-927. [16] ECCS-TWG7.9/CIB-W56European Recommendations forSandwich Panels[S]. [17] Davies J M.Fire and Cladding in Places of Public Assembly[J].New Steel Construction,1996(4/5):24-26. [18] GB/T239322009建筑用金属面绝热夹芯板国家标准[S]. [19] 邹杰.彩钢夹芯板的保温隔热及力学性能研究[D].哈尔滨:哈尔滨工业大学,2007:67-75. [20] 解维益.金属面绝热用夹芯板保温隔热和力学性能研究[D].哈尔滨:哈尔滨工业大学,2008:41-50. [21] 秦培成,余敏.夹芯板材料性能试验[R].哈尔滨工业大学深圳研究生院,2006. [22] 王洪欣,查晓雄.集成房屋的抗火性能及不同板材对其抗火性能的影响[J].工业建筑,2009,39(5):106-109. [23] 邹杰,查晓雄,阳松.金属面挤塑聚苯乙烯组合板热工性能分析[J].哈尔滨工业大学学报,2007,39(增刊):510-513. [24] 庄茁,由小川,廖剑晖.基于ABAQUS的有限元分析和应用[M].北京:清华大学出版社,2009:492-504. [25] Purkiss J A.Fire Safety Engineering Design of Structures[M].UK:Butterworth-Heinemann,2006. [26] 赵镇南.传热学[M].北京:高等教育出版社,2000:215-230.471-475. [27] Antonio Galagno,Colomba Di Blasi,Eva Milella.ThermalResponse to Fire of a Fibre-Reinforced Sandwich Panel:ModelFormulation,Selection of Intrinsic Properties and ExperimentalValidation[J].Polymer Degradation and Stability,2009,94:1267-1280.
点击查看大图
计量
- 文章访问数: 100
- HTML全文浏览量: 9
- PDF下载量: 102
- 被引次数: 0