EXPERIMENTAL RESEARCH AND BEARING CAPACITY ANALYSIS OF AXIALLY COMPRESSIVE REINFORCED CONCRETE-FILLED STEEL TUBE SHORT COLUMN
-
摘要: 在圆钢管混凝土柱内配置钢筋形成配筋圆钢管混凝土柱,可以进一步提高其承载能力,改善构件的塑性及延性。基于圆钢管混凝土的极限平衡理论,通过38个配筋圆钢管混凝土短柱轴压静载试验,揭示其受力机理和破坏形态,并对影响轴压承载能力的若干因素进行比较分析,探讨研究配筋圆钢管混凝土短柱轴压承载力计算方法,为后续研究和规范修订提供参考。Abstract: The axially compressive bearing capacity may be further enhanced,together with the plasticity and ductility also be improved by setting steel bars into circular concrete-filled steel tube column. Based on the limit equilibrium theory of concrete-filled steel tube column,the axially compressive static tests of 38 reinforced concretefilled steel tube short column specimens were carried out,in order to explore their bearing mechanism and failure modes. Some factors influencing the axial load-bearing capacity of the specimens are analyzed. The method of calculating the axial load-bearing capacity for this kind of short column is studied to provide a reference for the subsequent studies and the revision of correlative standards.
-
JCJ 0189 钢管混凝土结构设计施工及验收规程[S]. [2] CECS 28∶ 90 钢管混凝土结构设计与施工规程[S]. [3] DL /T 50851999 钢- 混凝土组合结构设计规程[S]. [4] GJB 41422000 战时军港抢修早强型组合结构技术规程[S]. [5] 蔡绍怀. 现代钢管混凝土结构[M]修订版. 北京:人民交通出版社,2003:11-54. [6] 韩金生,董毓利,徐赵东,等. 配筋钢管混凝土柱抗压性能[J]. 土木建筑与环境工程,2009,31(3) :12-17. [7] 余志武,丁发兴,林松. 钢管高性能混凝土短柱受力性能研究[J]. 建筑结构学报,2002,23(2) :41-47. [8] 韩林海. 钢管高强混凝土轴压力学性能的理论分析与试验研究[J]. 工业建筑,1997,27(11) :39-44. [9] 张春梅,阴毅,周云. 影响钢管混凝土柱轴压承载力的因素分析[J]. 工业建筑,2004,34(10) :66-68.