DURABILITY OF BASALT FIBER SHEETS UNDER ULTRAVIOLET LIGHT
-
摘要: 为了研究玄武岩纤维片材在紫外线照射下的耐久性能,对两种不同树脂浸渍的玄武岩纤维布共计70个试件在有、无防护的紫外线照射条件下进行老化试验。经过6464h的初步检测结果表明:无防护条件下,BFRP1拉伸强度下降了11.03%,伸长率下降了14.75%,弹性模量下降了5.23%;而BFRP2拉伸强度下降了2.02%,伸长率下降了13.73%,弹性模量提高了0.34%;有防护条件下,BFRP1拉伸强度下降了8.01%,伸长率下降了16.57%,弹性模量下降了1.38%;BFRP2的拉伸强度下降了1.51%,伸长率下降了9.59%,弹性模量下降了5.60%。因此,紫外线照射下玄武岩纤维布有较好的耐久性,防护对玄武岩纤维的性能有一定的保护作用。
-
关键词:
- 玄武岩纤维增强复合材料 /
- 紫外线照射 /
- 耐久性
Abstract: In order to study the durability of BFRP sheets under the conditions of ultraviolet light,ageing tests were done for a total of 70 BFRP sheets specimens impregnated by two different resins under the conditions of protection and without protection. The preliminary test results after 6464 h indicate that for BFRP1 under the conditions without protection,the tensile strength is decreased by 11.03% ,the extensibility is declined by 14.75% ,and Young's modulus is dropped by 5.23% ;while for BFRP2,the tensile strength is decreased by 2. 02% ,extensibility is declined by 13.73% ,and Young's modulus is increased by 0.34% ;under the conditions with protection,the tensile strength,extensibility and Young's modulus of BFRP1 is respectively dropped by 8.01% ,16.57% and 1.38% ; while the tensile strength,extensibility,and Young's modulus of BFRP2 are respectively dropped by 1.51% ,9.59% and 5.60%. Therefore,BFRP sheets have good durability under the ultraviolet light,protection has a protective effect on the properties of BFRP sheets.-
Key words:
- basalt fiber reinforced polymer /
- ultraviolet light /
- durability
-
[2] 岳清瑞,彭福明,杨勇新,等. 碳纤维片材耐久性初步研究[J].工业建筑,2004,34( 增刊) :8 - 11. Steckel G L,Hawkins G F,Bauer J L. Environmental Durability ofComposites for Seismic Retrofit of Bridge Columns. Proceedings ofNIST Workshop on Standards Development for the Use of FiberReinforced Polymers for Rehabilitation of Concrete and MasonryStructures[J]. Tucson,Arizona,1998(1 - 8) :83 - 96. [3] 杨勇新,郭春红,才鹏,等. 紫外线对CFRP 与混凝土粘结性能的影响[J]. 工业建筑,2006,36(8) :27 - 30. [4] 杨勇新,王敬,张小冬. 碳纤维布加固混凝土结构耐久性能初步研究[J]. 港工技术,2002(2) :25 - 27. [5] CECS 146∶ 2003 碳纤维片材加固修复混凝土结构技术规程[S]. [6] GB /T 33541999 定向纤维增强塑料拉伸性能试验方法[S]
点击查看大图
计量
- 文章访问数: 114
- HTML全文浏览量: 10
- PDF下载量: 107
- 被引次数: 0