STUDY ON CHECK EXPERIMENT OF MEASUREMENT METHODS FOR CHLORIDE DIFFUSION COEFFICIENT OF CONCRETE
-
摘要: 采用交流电桥法和NEL法及自然扩散法对5种配合比的水工普通混凝土进行氯离子扩散性对比试验。通过测得和计算的氯离子扩散系数,分析3种试验方法测得的氯离子扩散系数与水灰比、孔隙率和强度之间的相关性。结论表明,混凝土的氯离子扩散系数与水灰比、强度及孔隙率之间均存在较好的相关性;自然扩散法测试的扩散系数都要明显大于交流电桥法测试的结果,NEL法和交流电桥法的结论近似。Abstract: Using the alternating current bridge method and the NEL method and the natural diffusion method,the check experiments for chloride diffusion of ordinary hydraulic concrete with five mix proportions are tested.Based on the tested and calculated chloride diffusion coefficients,the correlation coefficients of chloride diffusion coefficients with the water cement ratios and porosity and compressive strengths of test concrete are studied.The results show there are better correlations among those parameters,the tested diffusion coefficients using the natural diffusion method are bigger than those diffusion coefficients using the bridge method,and the tested results using the NEL method are similar to the results by the bridge method.
-
[2] 杨医博,梁松,莫海鸿,等.混凝土抗氯离子渗透性能试验方法的探讨[J].中国港湾建设,2007(1):46-48. 董必钦,徐建芝.混凝土渗透性试验方法进展研究[J].混凝土,2008(1):40-44. [3] 杨进波,Folker H. WITTMAN N,赵铁军,等.混凝土氯离子扩散系数试验研究[J].建筑材料学报,2007,10(2):223-229. [4] DL /T 5150-2001水工混凝土试验规程[S]. [5] 路新瀛,张华新,王晓睿.混凝土渗透性电测方法评述[J].混凝土与水泥制品,2003(4):7-9. [6] Otsukin,Hisada M,Otani T,et a.l Theoretical Evaluation of Diffusion Coefficient of Chloride Ironin Mortar from Mobility[J].ACI Material Journal 1999,96(6):627-633. [7] 赵铁军.混凝土渗透性[M].北京:科学出版社,2006. [8] 张俊芝,王建泽,周建民,等.自然环境下既有混凝土的氯离子侵蚀及随机性研究[J].工业建筑,2009,39(3):77-80. [9] 刘志勇,孙伟.基于饱海水电阻率的海工混凝土氯离子扩散系数测试方法的试验研究[J].混凝土,2005(4):26-28,57.
点击查看大图
计量
- 文章访问数: 157
- HTML全文浏览量: 12
- PDF下载量: 63
- 被引次数: 0