摘要: 对7个带约束拉杆和2个不设约束拉杆矩形钢管混凝土短柱进行偏心受压试验研究,主要研究偏心率、约束拉杆水平间距对矩形钢管混凝土短柱偏压性能的影响。试验研究结果表明,在偏心压力作用下,约束拉杆的设置有助于提高矩形钢管混凝土短柱的延性,延迟钢管的局部屈曲。带约束拉杆矩形钢管混凝土柱的偏压承载力随偏心率的增大而减小。在相同偏心率下,试件延性随拉杆水平间距减小而增大。Abstract: The experiments of seven rectangular CFT stub columns with binding bars and two without binding bars eccentrically loaded in compression were carried out with the main parameters such as eccentricity ratio and binding bar horizontal spacing.Experimental results indicate that binding bars increase the ductility of rectangular columns under eccentric load and delay the local buckling of steel tubes.The ultimate capacity decreases with load eccentricity ratios increasing.When load eccentricity ratios are the same,the ductility increases with binding bar horizontal spacing decreasing.
-
Key words:
- rectangular CFT /
- binding bar /
- ductility /
- bearing capacity
-
[2] Knowles R B,Park R.Strength of Concrete-Filled Steel TubularColumns[J].J Struct Div,ASCE,1969,95(ST12):2565-2587. Forlong R W.Strength of Steel-Encased Concrete Beam-Columns[J].J Struct.Div.,ASCE,1967,93(ST5):113-124. [3] Schneider S P.Axially Loaded Concrete-Filled Steel Tubes[J].JStruct Eng,1998,124(10):1125-1138. [4] Uy B.Strength of Short Concrete Filled High Strength Steel BoxColumns[J].J Construct Steel Res,2001,57(2):114-134. [5] Sakino K,Nakahara H,Morino S,et al.Behaviour of CentrallyLoaded Concrete-Filled Steel-Tube Short Columns[J].J Struct Eng,2004,130(2):180-188. [6] 张正国.方钢管混凝土轴压柱的机理和承载力分析[J].工业建筑,1989,19(11):2-7. [7] 韩林海,陶忠.方钢管混凝土轴压力学性能的理论分析与试验研究[J].土木工程学报,2001,34(2):17-25. [8] 何振强,蔡健.带约束拉杆方钢管混凝土轴压短柱的承载力计算[J].工业建筑,2008,38(3):12-15. [9] Cai Jian,Long Yueling.Axial Load Behavior of Rectangular CFTStubColumns with Binding Bars[J].Advances in Structural Engineering,2007,10(5):551-565. [10] 蔡健,龙跃凌.带约束拉杆矩形钢管混凝土的本构关系[J].工程力学,2008,25(2):137-143. [11] 蔡健,何振强.带约束拉杆方形钢管混凝土柱偏压性能[J].建筑结构学报,2007,28(4):25-35. [12] CECS 159∶2004矩形钢管混凝土结构技术规程[S]. [13] DBJ 13512003钢管混凝土结构技术规程[S]. [14] GJB41422000战时军港抢修早强型组合结构技术规程[S]. [15] Park R.Evaluation of Ductility of Structures and Structural Sub-Assemblage fromLaboratory Testing[J].Bull of the NewZealand Socfor Earthquake Engrg,1989,22(3):155-166.
点击查看大图
计量
- 文章访问数: 59
- HTML全文浏览量: 3
- PDF下载量: 57
- 被引次数: 0