ANALYSIS OF EFFECT FACTOR ON SEISMIC BEHAVIOR OF ABNORMAL INTERIOR JOINTS IN REINFORCED CONCRETE FRAME STRUCTURES
-
摘要: 通过6个钢筋混凝土框架异型中节点试件在低周反复荷载作用下的试验,分析节点核心区尺寸、轴压比等因素对异型节点抗震性能的影响。研究表明:上柱截面发生变化对异型节点抗震性能的影响不明显,当其变化量小于1/6柱高时,即hchc/6,可忽略其不利作用;小梁截面发生变化对组合体试件的抗震性能影响较大,当大小梁截面高差在1/6柱高到2/5梁高时,即hc/6hb2hbl/5,随着大小梁高差的增大,组合体的抗震性能将逐渐改善;当2hbl/5hbhbl/2时,随着大小梁高差的增大,组合体的抗震性能将逐渐劣化;当hbhbl/2时,建议按中间层边节点考虑。此外,轴压比增大对异型节点通裂阶段后组合体试件的抗震性能产生不利影响,对该类节点进行抗震设计时,建议轴压比应小于0.3。Abstract: Six specimens of abnormal interior joints were tested under reversed cyclic loading.Experimental studies were carried out to investigate the effect of joint core dimensions and axial compression ratio on seismic behaviour of abnormal joints.Test results indicated that column section abrupt had little effect on seismic behavior of the specimen.When the reduced height of column section was less than 1/6 column section height,that is h_ch_c/6,the negative effect of that could be neglected.The test results also indicated that beam section abrupt had an obvious effect on seismic behavior of the beam-column subassemblage. When h_b was between h_c/6 and 2h_(bl)/5,the seismic behavior improved gradually with the increase of h_b;When h_b was between 2h_(bl)/5 and h_(bl)/2,the seismic behavior deteriorated with the increase of h_b;When h_b was greater than 1/2 high beam section depth,a exterior joint model would be better for this case analysis.In addition,the axial load level of the column had a negative effect on seismic behavior of abnormal joints after the beam-column subassemblage reached to critical crack stage,it was suggested that the axial compression ratio shoulds be less than 0.3 for the seismic design of this sort of abnormal joint.
-
GB500102002混凝土结构设计规范[S]. [2] GB500112001建筑抗震设计规范[S]. [3] 吴涛,刘伯权,白国良,等.大型厂房钢筋混凝土框排架结构中异型节点的抗震性能和设计方法研究[J].土木工程学报,2006,39(4):1-5. [4] 框架节点专题研究组.低周反复荷载作用下钢筋混凝土框架梁柱节点核心区抗剪强度的试验研究[J].建筑结构学报,1983,4(6):1-17. [5] 唐九如.钢筋混凝土框架节点抗震[M].南京:东南大学出版社,1989:31-32.
点击查看大图
计量
- 文章访问数: 74
- HTML全文浏览量: 12
- PDF下载量: 54
- 被引次数: 0