EXPERIMENTAL STUDY ON THE STRENGTHENED COMPOSITE BEAM JOINTED WITH WELDED SHORT REBAR
-
摘要: 参照成熟的加大截面加固施工工艺,连接件选用焊接短筋,制作了2根下托槽钢加固组合梁,1根未加固钢筋混凝土梁对比梁进行试验研究和计算分析。试验采用实验室室内模型短期静载试验,主要观测了采用焊接短筋连接的下托型钢加固组合梁的极限承载力、抗弯刚度、裂缝情况、跨中截面荷载-应变分布情况等。从试验结果可以看出:下托型钢与原钢筋混凝土梁协同工作的性能良好;焊接短筋连接的下托型钢加固组合梁极限承载力和抗弯刚度大幅提高,裂缝开展也得到有效控制。Abstract: According to the technics of structure member strengthened with R.C,it is designed that two pieces of composite beams by shaped-steel underpinning(CBSSU) jointed with welded short reinforcing steel bars and one R.C beam in order to contrast their experimentation and analysis.The short period loading test by indoor model is used,and it is observed that several parameters of these beam behaviors,such as limit loadbearing capacity,bending stiffness,flaw condition and stress-strain in the middle section of the beam.On the basis of the experimental study,it can be found that the shaped-steel works in coordination with the R.C beam very well.The CBSSU jointed by welded short reinforcing steel bar gains better bending stiffness,higher limit load-bearing capacity and flaw of the beam can be controlled effectively.
-
Key words:
- welded short rebar /
- shaped-steel underpinning /
- strengthening /
- composite beam /
- bending resistance /
- stiffness
-
[2] Yam L C P,Chapman J C.The Inelastic Behaviour of ContinuousComposite Beams of Steel and Concrete[J].Porc.Inst.Civil Engrs.Londen,1972,53:487-501; 将松岩,莫群速,王秉权,等.结构加固胶的老化与耐久性研[C]∥第八届全国建筑物加固改造学术会议论文集.2006:569-574; [3] 王挺,聂建国,李炳益,等.钢-压型钢板混凝土组合梁极限抗弯承载力的研究[J].建筑结构学报,2001,22(2):61-65; [4] 聂建国,沈聚敏,余志武.考虑滑移效应的钢-混凝土组合梁变形计算的折减刚度法[J].土木工程学报,1995,28(6):12-18; [5] 朱聘儒.钢-混凝土组合梁设计原理[M].第二版.北京:中国建筑工业出版社,2006; [6] 王连广.钢与混凝土组合结构理论与计算[M].北京:科学出版社,2005.
点击查看大图
计量
- 文章访问数: 89
- HTML全文浏览量: 6
- PDF下载量: 50
- 被引次数: 0