RESIDUAL STRENGTH OF CONCRETE-FILLED DOUBLE-SKIN STEEL TUBULAR STUB COLUMNS AFTER EXPOSURE TO FIRE
-
摘要: 对6个中空夹层钢管混凝土轴压短柱开展试验研究,试验的主要参数是截面形式(圆套圆、方套方和方套圆)以及受火与否。试验结果表明,受火后中空夹层钢管混凝土轴压短柱的承载力下降显著。在空心率相同的情况下,方套圆截面形式的试件其剩余承载力最高,而圆套圆截面形式的试件其延性最好。同时还可以发现,火灾后中空夹层钢管混凝土的轴压承载力下降幅度与传统的实心钢管混凝土接近。Abstract: Test results of six concrete-filled double-skin steel tubular(CFDST) stub columns are presented.Circular hollow sections(CHS) and square hollow sections(SHS) were used to fabricate the inner and outer skins of the composite columns.The main parameters explored in this test programme were the section type(CHS inner and CHS outer,SHS inner and SHS outer,and CHS inner and SHS outer) and whether or not exposure to fire.It was found that the strength of the CFDST columns decreased significantly after exposure to fire.However,the residual strength of these innovative CFDST columns was still comparable to that of conventional concrete-filled steel tubular columns.Of all the three types of sections with a same hollow section ratio,the one with CHS inner and SHS outer shown the highest residual strength,whilst that with CHS inner and CHS outer shown the best ductility behaviour.
-
Key words:
- concrete-filled steel tube /
- stub column /
- fire exposure /
- double-skin /
- post-fire residual strength
-
陶忠,于清.新型组合结构柱--试验、理论与方法[M].北京:科学出版社,2006; [2] Han L H,Tao Z,Zhao X L,Concrete-Filled Double Skin(SHS Outerand CHS Inner)Steel Tubular Beam-Columns[J].Thin-WallStructures,2004,42(9):1329-1355; [3] Tao Z,Han L H,Zhao X L,Behaviour of Concrete-Filled Double Skin(CHSInner and CHS Outer)Steel Tubular Stub Columns and Beam-Columns[J].Journal of Constructional Steel Research,2004,60:1129-1158; [4] 赵均海,郭红香,魏雪英.圆中空夹层钢管混凝土柱承载力研究[J].建筑科学与工程学报,2005,22(1):50-54; [5] 杨俊杰,徐汉勇,彭国军.八边形中空夹层钢管混凝土轴压短柱力学性能的研究[J].土木工程学报,2007,40(2):33-38; [6] Yang Y F,Han L H.Concrete-Filled Double-Skin Tubular ColumnsUnder Fire[J].Magazine of Concrete Research,2008,60(3):211-222; [7] ISO-834.Fire-Resistance Tests-Elements of Building Construction-Part 1:General Requirements[S].International Organization forStandardization,Geneva,Switzerland,1999; [8] Han L H,Huo J S.Concrete-Filled Hollow Structural Steel ColumnsAfter Exposure to ISO-834 Standard Fire[J].Journal of StructuralEngineering,ASCE,2003,129(1):68-78; [9] Lie T T.Fire Resistance of Circular Steel Columns Filled with Bar-Reinforced Concrete[J].Journal of Structural Engineering,1994,120(5):1487-1509; [10] Lie TT,Chabot M.AMethodto Predictthe Fire Resistance of CircularConcrete Filled HollowSteel Columns[J].Journal of Fire ProtectionEngineering,1990,2(4):111-126.
点击查看大图
计量
- 文章访问数: 140
- HTML全文浏览量: 16
- PDF下载量: 118
- 被引次数: 0