摘要: 采用直接强度法分析了近期完成的62根550 MPa高强冷弯薄壁型钢轴压柱的试验结果,提出了采用折减材料屈服强度为0.85fy,并根据修正长细比c=0.85fy/235查《冷弯薄壁型钢结构技术规范》(GB 50018-2002)中Q235钢稳定系数表来计算高强冷弯型钢轴压构件稳定承载力的计算方法。该建议方法计算值与试验结果吻合较好且偏于安全。Abstract: The experimental results of 62 specimens with 550 MPa high strength cold-formed thin-wall steel under axial compression are analyzed by direct strength method(DSM).The bearing capacities of high strength cold-formed thin-walled steel columns under axial compression are calculated by reduced yield strength 0.85f_y and revised slenderness ratio _c=0.85f_y/235 for the stability coefficient from the stability coefficient table of Q235 in Technical Code for Cold-Formed Thin Walled Section Steel Stucture(GB 50018-2002).The calculated results by the suggested method are closed well to the test results.
-
[2] Yang Deman,Hancock G J.Compression Tests of Cold-Reduced High Strength Steel Sections:l-Stub Columns.Journal of Structural Engineering,2004,130(11):1 772-1 781 CB 50018-2002 冷弯薄壁型钢结构技术规范 [3] Schafer B,Pekoz T.Laterally Braced Cold-Formed Steel Flexurat Members with Edge Stiffened Elements.Journal of Structural Engineering,ASCE,1999,125(2):118-127 [4] Hancock G J,Murray T M,Ellifritt D S,et at.Cold-Formed Steel Structures to the AISI Specification.Marcel Dekker,New York:2001 [5] Design of Cold-Formed Steel Structural Members Using the Direct Strength Method.Appendix 1 of NAS 2004.American Iron and Steel Institute,Canadian Standards Association,2004 [6] 周天华,周绪红,何保康,等.G550级高强薄板钢材的材性及应用.建筑科学与工程学报,2005,22(2):43-46 [7] Schafer B W.Elastic Buckling Analysis of Thin-Walled Members by Finite Strip Analysis.CUFSM v2.6,2002 [8] 张中权.冷弯薄壁型钢轴心受压构件的稳定性.建筑结构学报,1991(2):72-79 [9] 沈祖炎,李元齐,王磊,等.屈服强度550 MPa高强冷弯薄壁型钢轴心受压构件可靠度分析.建筑结构学报,2006,27(3):26-33
点击查看大图
计量
- 文章访问数: 82
- HTML全文浏览量: 13
- PDF下载量: 75
- 被引次数: 0