TEST ON BEAM-COLUMN CONNECTION BY TOP AND SEAT ANGLESWITH STIFFER AND DOUBLE WEB ANGLES
-
摘要: 通过带加劲肋的顶底角钢和腹板双角钢连接的梁柱节点静力荷载试验,分析顶底角钢、顶底角钢加劲肋、腹板角钢、梁柱翼缘和腹板在荷载作用下的应力情况,确定这种连接的受力性能及破坏模式,得到此类连接的M-曲线、连接初始刚度、极限承载力和极限转角,讨论了加劲肋及其他因素对连接性能的影响。Abstract: According to static load test on a beam-column connection by top and seat angles with stiffer and double web angles, it is analyzed that the stresses on the top and seat angles, stiffer, web angles, beam flange and web, column flange and web. The static behavior and failure mode of the sem-i rigid connection are determined, and the M-H relation, the initial stiffness, the ultimate bearing capacity and the ultimate rotation are obtained. The stiffeners and other factors which influence the static behavior of the connection are discussed.
-
Key words:
- semi-rigid connection /
- initial stiffness /
- ultimate bearing capacity /
- stiffener /
- test research
-
[2] GB 6397-86 金属拉伸试验试样 GBPT 2975-1988 钢及钢产品力学性能试验取样位置及试样制备 [3] GB 228-87 金属拉伸试验方法 [4] JGJ 82-91 钢结构高强度螺栓的设计、施工及验收规程 [5] GBPT 1228-91 钢结构用高强度大六角头螺栓 [6] JGJ 101-96 建筑抗震试验方法规程 [7] 刘 曙, 尹 静, 朱洪波. 钢框架顶底角钢带腹板双角钢连接的试验研究. 华中科技大学学报, 2004, 32(7) : 108-110
点击查看大图
计量
- 文章访问数: 132
- HTML全文浏览量: 4
- PDF下载量: 82
- 被引次数: 0