STRUCTURE DETECT AND COMPUTATION ANALYSIS OF THE SKEW BRIDGE IN A PUDDLING FURNACE
-
Abstract: The skew bridge in a puddling furnace was found to have heavy vibrations when it was working, also it had common structural damages, after structure inspecting, vibration test and computation analysis, the scheme of structural disposal was proposed.
-
Key words:
- structural vibration test /
- steel truss /
- structure computation
-
[2] GBJ 144-90 工业厂房可靠性鉴定标准 中冶集团建筑研究总院(国家工业建筑诊断与改造工程技术研究中心). 某钢1 高炉斜桥结构检测鉴定报告 [3] GBPT 50344-2004 建筑结构检测技术标准 [4] YB 9257-96 钢结构检测评定及加固技术规程 [5] GB 50009-2001 建筑结构荷载规范 [6] GB 50017-2003 钢结构设计规范
点击查看大图
计量
- 文章访问数: 70
- HTML全文浏览量: 4
- PDF下载量: 63
- 被引次数: 0